Investigation on the source of VOCs emission from indoor construction materials using electronic sensors and TD-GC-MS
E A Elia1, M Stylianou2, A Agapiou1
1Department of Chemistry, University of Cyprus, P.O. Box 20537, Nicosia, 1678, Cyprus.
Abstract:
Indoor air quality (IAQ) is critical to the health and wellbeing of people. As the majority of people spend greater amounts of time indoors, either in office spaces or households, the level of air pollutants in such environments is critical. Building materials and furniture are known sources of air pollutants such as Volatile Organic Compounds (VOCs) and may be associated with discomfort, detrimental health of the occupants, etc. In this study, the VOCs found in a brand new office complex were monitored over a period of 6 months, with an emphasis on monitoring and quantifying harmful VOCs and identifying their emission source. Air samples were taken from a closed, unoccupied office space on a weekly basis and analysed using Thermal Desorption-Gas Chromatography-Mass Spectrometry (TD-GC-MS), while continuous monitoring of the air quality was performed using two commercially available IAQ sensors. To identify the source of the emitted VOCs, pieces of all construction material that were used in the office, including flooring, finished wall material, and adhesive glues, were removed, and placed in air-tight glass containers prior to analysis confirming that the source of VOCs is indeed the flooring. Identified compounds included mainly material origin VOCs such as BTEX (benzene, toluene, ethylbenzene, xylene) and styrene, but also common VOCs such as acetone and propan-2-ol. Of significant importance was the concentration of toluene that was found to be the most abundant VOC in both the flooring material and the indoor air.
More Related Videos
08:23Real-time Breath Analysis by Using Secondary Nanoelectrospray Ionization Coupled to High Resolution Mass Spectrometry
Published on: March 9, 2018
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...