Related Experiment Video
Updated: Jun 29, 2025

Author Spotlight: Advancing Understanding of Age-Related Lens Stiffness Changes
Published on: April 5, 2024
Corneal stress-strain index in myopic Indian population
Vaishal P Kenia1, Raj V Kenia2, Pradnya Bendre1
1Department of Cataract and Refractive Surgery, Kenia Eye Hospital, Mumbai, Maharashtra, India.
Aim:
The purpose is to study the corneal stress-strain index (SSI) in myopic refractive error among Indian subjects.
Methods:
A retrospective study where young myopic subjects aged between 11 and 35 years who had undergone corneal biomechanics assessment using Corvis ST between January 2017 and December 2021 were enrolled. Subjects with central corneal thickness (CCT) <500 μ, intraocular pressure (IOP) >21 mmHg, history of any systemic and ocular disease or any previous ocular surgery, high astigmatism, corneal disease such as keratoconus were excluded. Subjects with missing data or having poor quality scan were excluded. Corneal biomechanical properties and corneal SSI were assessed using Corvis ST. For statistical purposes, eyes were divided into four different groups and were analyzed using one-way ANOVA.
Results:
Nine hundred and sixty-six myopic eyes with mean ± standard deviation age, IOP, and CCT of 26.89 ± 4.92 years, 16.94 ± 2.00 mmHg, and 540.18 ± 25.23 microns, respectively, were included. There were 311, 388, 172, and 95 eyes that were low, moderate, severe, and extreme myopic. Deformation amplitude ratio at 1 mm and 2 mm were similar across different myopic groups. A significant increase in max inverse radius, ambrosia relational thickness, biomechanically corrected IOP, integrated radius was noted with an increase in myopic refractive error. Corvis biomechanical index, corneal SSI was found to be decreased significantly with an increase in myopic refractive error. We noted a significant positive association between myopic refractive error and SSI (P < 0.001).
Conclusion:
Corneal SSI was found to be reduced in extreme myopic eyes.
More Related Videos
07:51Full-Field Optical Coherence Microscopy for Histology-Like Analysis of Stromal Features in Corneal Grafts
Published on: October 21, 2022
04:00Author Spotlight: Establishing a Practical and Cost-Effective Protocol for Corneal Sensitivity Testing in Clinical Settings
Published on: August 2, 2024
Related Concept Videos
Focusing of Light in the Eye
Three-Dimensional Analysis of Strain