Related Experiment Video
Updated: Jul 9, 2026

Assessing Early Stage Open-Angle Glaucoma in Patients by Isolated-Check Visual Evoked Potential
Published on: May 25, 2020
The Relationship Between Artificial Intelligence-Assisted OCT Angiography-Derived Foveal Avascular Zone Parameters
Takahiro Ninomiya1, Naoki Kiyota1, Parmanand Sharma1
1Department of Ophthalmology, Tohoku University Graduate School of Medicine, Miyagi, Japan.
Purpose:
To investigate clinical factors associated with foveal avascular zone (FAZ) parameters obtained using OCT angiography (OCTA) with assistance from a previously developed artificial intelligence (AI) platform in eyes with open-angle glaucoma (OAG).
Design:
Retrospective longitudinal.
Participants:
This study followed up 885 eyes of 558 patients with OAG for ≥ 2 years; all eyes underwent ≥ 5 Humphrey visual-field (VF) tests and had 3.0 × 3.0 mm macular OCTA scans available.
Methods:
Average total deviation (TD) in the superior, superocentral, inferocentral, and inferior sectors of the Humphrey 24-2 program was calculated. We collected 3.0 × 3.0 mm macular OCTA images from each patient and used a previously developed AI platform with these images to obtain FAZ parameters, including FAZ area, FAZ circularity index (CI), and FAZ perimeter. Multivariable linear mixed-effects models were used to analyze the relationship between FAZ parameters, TD or TD slope in each quadrant, and systemic factors, adjusting for potential confounding factors, including axial length.
Main Outcome Measures:
Ophthalmic and systemic variables, FAZ parameters, and TD or TD slope in each quadrant.
Results:
The multivariable model showed that FAZ parameters were correlated with both TD and TD slope in the inferocentral quadrant (β = -0.244 - 0.168, P < 0.001). Both upper-half and lower-half FAZ parameters were better associated with TD-inferocentral and TD-inferocentral slope than TD-superocentral or TD-superocentral slope in terms of β size and statistical significance, indicating that there was no evident vertical anatomical correspondence between TD in the central quadrant and FAZ parameters. Foveal avascular zone area enlargement was associated with female gender (β = 0.242, P = 0.003). Loss of FAZ circularity was associated with both aging and comorbid sleep apnea syndrome (SAS) (yes: 1, no: 0) (β = -0.188, P < 0.001; β = -0.261, P = 0.031, respectively). Foveal avascular zone perimeter elongation was associated with aging and female gender (β = 0.084, P = 0.040; β = 0.168, P = 0.042, respectively).
Conclusions:
Artificial intelligence-assisted OCTA-measured FAZ enlargement and irregular shape might be good markers of ocular hypoperfusion and associated inferocentral VF defect progression in eyes with OAG. The author(s) have no proprietary or commercial interest in any materials discussed in this article.
More Related Videos
07:18Evaluation of Capillary and Other Vessel Contribution to Macular Perfusion Density Measured with Optical Coherence Tomography Angiography
Published on: February 18, 2022
08:54Author Spotlight: Understanding Age-Related Macular Degeneration Pathophysiology with QAF Workflow
Published on: May 26, 2023
Related Concept Videos
Glaucoma: Overview
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Angle Closure Glaucoma: Treatment