Optimal topology control for grounding protection sensor networks in shipboard electrical systems
Benxiang Wu1, Geng Li1, Jianhua Wu2
1Naval University of Engineering, Wuhan, Hubei, China.
Abstract:
Intelligent monitoring of environmental information in ships is an important prerequisite for reducing and avoiding accidents and is of great importance for safety at sea. The use of a ship environmental monitoring system based on wireless sensor networks has the unique advantages of low cost, stability, and reliability, allowing real-time monitoring of many environmental factors in ships. This article proposes an optimal topology control to maximize collected data satisfaction and reduce energy consumption and transmission latency. First, the cluster head selection method is obtained by initializing the wireless sensor network with a fuzzy clustering algorithm, then the amount of collection data is obtained by a sub-gradient descent algorithm, and a sensor association scheme based on ant colony optimization is proposed to solve the knapsack problem. Finally, simulation results show that the proposed algorithm in this article can effectively reduce the energy consumption and transmission delay of the wireless sensor network while ensuring the monitoring of the grounding protection in the electrical system of the offshore ship.
More Related Videos
05:30Large Scale Energy Efficient Sensor Network Routing Using a Quantum Processor Unit
Published on: September 8, 2023
10:52Design, Instrumentation and Usage Protocols for Distributed In Situ Thermal Hot Spots Monitoring in Electric Coils using FBG Sensor Multiplexing
Published on: March 8, 2020
Related Concept Videos
Zones of Protection
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Line Protection with Impedance Relays
Under normal conditions, low load currents keep the measured...
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Electrical Systems
To derive the transfer function, consider...
Reclosers and Fuses
A comprehensive protection scheme for radial distribution...
Insulation Coordination