Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
Published on: June 9, 2016
Magnetic Particle Spray Mass Spectrometry
Tássia Venga Mendes1, Eduardo Costa Figueiredo1
1Laboratory of Toxicant and Drug Analyses, Faculty of Pharmaceutical Sciences, Federal University of Alfenas, 37130-000 Alfenas, MG Brazil.
Abstract:
In this work, the concept of magnetic particle spray mass spectrometry (MPS-MS) is reported for the first time. Magnetic sorbent particles are used to extract the analytes from a liquid sample. The particles are magnetically attracted to the tip of a magnetic probe that is positioned at the entrance of the mass spectrometer. A solvent is dispensed on the particles, and a high voltage promotes the formation of the Taylor cone around the particles agglomerate. Analytes are desorbed by the solvent, ionized, and analyzed by mass spectrometry. MPS-MS is totally in consonance with the green chemistry principle. A minimal consumption of sample (100 μL), solvent (34 μL), and magnetic sorbent (500 μg) is needed per analysis for an excellent performance of MPS-MS in terms of sensitivity and selectivity. The determination of amitriptyline, citalopram, clomipramine, chlorpromazine, doxepin, haloperidol, nortriptyline, and venlafaxine in human plasma samples using magnetic restricted-access carbon nanotubes was carried out as a proof of principle. Limits of quantification of 10 μg L-1 and correlation coefficients higher than 0.98 were obtained for all of the analytes. Limits of detection ranged from 0.43 to 2.82 μg L-1. Precision (as relative standard deviation) and accuracies (as relative error) ranged from 3.6 to 23.6%, as well as -12.8 to 18.7%, respectively. MPS-MS opens a new line of developments in the association of sample preparation with ambient ionization. New sorbents, device configurations, and physical and chemical conditions can also be analyzed for the analysis of many other analytes in different samples.
Related Concept Videos
Mass Spectrometers
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Mass Spectrometry: Overview
Mass Analyzers: Overview
Tandem Mass Spectrometry
Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called collision-induced...
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview