Background:
Exposure to excessive noise volumes is an occupational health and safety risk. Australian guidelines recommend a time weighted exposure maximum of 85 dB (dB) or a maximum peak noise level of up to 140 dB, as chronic and repeated high dB exposure can result in significant hearing impairment. The aim of this study was to assess the volume of noise generated by common surgical instruments while utilizing the National Institute for Occupational Safety and Health (NIOSH) app.
Methods:
Sound levels were measured using the NIOSH app. The NIOSH app was used to take equivalent continuous A-weighted sound levels (LAeq) and the C-weighted peak sound pressure (LCpeak) measurements for specific instruments while in use in theatre. A minimum of three readings per instrument were taken at immediate and working distances.
Results:
LAeq measurements ranged from 62.9 to 89.3 dB. The Padgett Dermatome and Frazier Sucker exceeded recommended exposure limits with an averaged LAeq reading of 85.7 dB(A) and 85.1 dB(A) respectively. LCpeak readings ranged from 89.9 to 114.7 dB(C) with none of the instruments exceeding a peak sound level beyond the recommended level of 140 dB(C).
Conclusion:
The cumulative effect of loud surgical instruments across prolonged or combined operations may result in theatre staff being exposed to hazardous noise levels, impacting the health and wellbeing of staff, staff performance and patient care. Utilization of a phone app can improve the awareness of noise pollution in theatres, thereby empowering staff to be proactive about their health and improvement of their work environment.
More Related Videos
03:49Author Spotlight: Optimizing EAS with Long Electrodes for Enhanced Cochlear Coverage and Hearing Preservation
Published on: October 11, 2024
12:21The Mouse Round-window Approach for Ototoxic Agent Delivery: A Rapid and Reliable Technique for Inducing Cochlear Cell Degeneration
Published on: November 26, 2015
Related Concept Videos
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...