Simultaneous brain and neck time-of-flight MRA using spiral multiband with localized quadratic encoding
Xi Peng1,2, Dinghui Wang1, Daniel Borup3
1Department of Radiology, Mayo Clinic, Rochester, Minnesota, USA.
Magnetic Resonance in Medicine
|April 5, 2024
Summary
This study introduces a fast magnetic resonance angiography (MRA) technique for simultaneous brain and neck imaging. The novel method significantly reduces scan time and venous signal contamination for clearer artery visualization.
Area of Science:
- Medical Imaging
- Radiology
- Neuroimaging
Background:
- Time-of-flight magnetic resonance angiography (ToF-MRA) is crucial for visualizing blood vessels.
- Simultaneous brain and neck MRA is challenging due to time constraints and potential signal interferences.
Purpose of the Study:
- To develop an efficient method for simultaneous brain and neck ToF-MRA.
- To achieve this within practical scan timeframes.
Main Methods:
- A spiral multiband (MB) localized quadratic (LQ) encoding method was proposed.
- Tilt-optimized non-saturated excitation (TONE) and partial-Fourier slice selection (PFSS) were integrated to reduce venous signal contamination.
- A sequential spiral MB and LQ reconstruction pipeline was utilized.
Main Results:
- Simultaneous brain and neck ToF-MRA was achieved in 2 minutes and 50 seconds.
- The MB and LQ acquisitions enhanced SNR-efficiency, allowing for greater spatial coverage without compromising scan time or SNR.
- TONE and PFSS effectively minimized venous contamination and improved sensitivity to small vessels.
Conclusions:
- A novel MB spiral LQ approach enables rapid intracranial and carotid ToF-MRA with reduced venous interference.
- This method shows significant promise for MRA applications requiring extensive spatial coverage.
Related Concept Videos
NMR Spectrometers: Radiofrequency Pulses and Pulse Sequences
A pulse is a short burst of radio waves distributed over a range of frequencies that simultaneously excites all the nuclei in the sample. Upon passing a radio frequency pulse along the x-axis, the nuclei absorb energy corresponding to their Larmor frequencies and achieve resonance. This shifts the net magnetization vector from the z-axis toward the transverse plane. This angle of rotation of the magnetization vector, or the flip angle, is proportional to the duration and intensity of the pulse.
Pilot and Numeric Relaying
Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying: