A proposed numerical method for absolute efficiency calibration of α-spectrometers and its application for activity
K M El-Kourghly1, W El-Gammal1, Mohamed M Damoom2,3
1Nuclear Safeguards and Physical Protection Department, Egyptian Atomic Energy Authority (EAEA), Cairo, Egypt.
Abstract:
In this work, an absolute method to calibrate an α-spectrometer is proposed taking into account the Source-to-Detector, and lateral distances due to eccentric source distribution. An analytical formula to calibrate an α-spectrometer is derived and the Simpson's integration method was utilized to solve these equations in its integral form numerically using a written C computer code. The general Monte Carlo N-particle code, MCNP as well as experimental measurements for some standard α-emitters are used to benchmark the proposed method. An agreement was found between the efficiency results calculated by MC and the proposed method with a maximum relative difference of about 0.5%. While, experimental measurement of α-emitters activity employing the proposed method differs by about 1.65% from the certified values. Accounting for the man made error allows to accurately quantify the assayed sample. Therefore, the inaccuracy in the efficiency results due to non-accurate inputs pertained to the source, and detector radii, Source-Detector distances, and eccentric source distribution are investigated in the Source-to-Detector distance range of (4 to 44 mm). The results show that a difference of in the detector radius, and Source-to-Detector distance than the normal values yields a relative difference of about , while a difference of in the source radius or source lateral distance from detector symmetry axis could only yields inaccuracy of less than in the efficiency results.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Emission Spectroscopy: Overview
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Atomic Emission Spectroscopy: Lab