Related Experiment Video
Updated: May 7, 2025

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
Absolute calibration methodology for non-uniform uranium and matrix distributions in large barrels of uranium-bearing
1Nuclear Safeguards and Physical Protection Department, Egyptian Atomic Energy Authority (EAEA), Cairo, Egypt. kamel.elkourghly@eaea.sci.eg.
Abstract:
The effective implementation of domestic and international safeguards necessitates verification techniques for Nuclear Materials (NM). Even in the case of very small quantities of NMs, accounting for and analyzing such traces can provide insights into the mass balance of NMs and/or state activities, ensuring consistency in state declarations. This paper proposes and benchmarks an absolute calibration methodology for estimating the uranium-mass content in large-volume barrels (200 L). These barrels may be generated during the operation and decommissioning of bulk handling facilities by accumulating low-density scarab contaminated with NMs. The method relies on the mathematical calibration of a High Purity Germanium (HPGe) detector efficiency against non-uniform uranium and matrix distributions, assuming that the non-uniform distribution can be approximated as a uniform one for low-density matrix materials. The peak efficiency is calculated for different numbers of point sources 1-30 likely distributed inside a simulated barrel while it rotates around the axis of symmetry. The proposed method is benchmarked by comparing the calculated peak efficiency of randomly distributed uranium sources with the homogeneous distribution. Furthermore, a comparison with experimental measurements is conducted to validate the proposed method. Results show that the proposed calibration method considering either random or homogeneous source and matrix distributions in large volume barrels can be used for estimating the uranium mass content in NSW with an accuracy of approximately 12 %.
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Calibration Curves: Linear Least Squares
For data that follow a straight line, the standard method for fitting is the linear...

