Vision transformer to differentiate between benign and malignant slices in 18F-FDG PET/CT
Daiki Nishigaki1, Yuki Suzuki1, Tadashi Watabe2
1Department of Artificial Intelligence Diagnostic Radiology, Osaka University Graduate School of Medicine, Suita, Osaka, Japan.
Abstract:
Fluorine-18-fluorodeoxyglucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) is widely used for the detection, diagnosis, and clinical decision-making in oncological diseases. However, in daily medical practice, it is often difficult to make clinical decisions because of physiological FDG uptake or cancers with poor FDG uptake. False negative clinical diagnoses of malignant lesions are critical issues that require attention. In this study, Vision Transformer (ViT) was used to automatically classify 18F-FDG PET/CT slices as benign or malignant. This retrospective study included 18F-FDG PET/CT data of 207 (143 malignant and 64 benign) patients from a medical institute to train and test our models. The ViT model achieved an area under the receiver operating characteristic curve (AUC) of 0.90 [95% CI 0.89, 0.91], which was superior to the baseline Convolutional Neural Network (CNN) models (EfficientNet, 0.87 [95% CI 0.86, 0.88], P < 0.001; DenseNet, 0.87 [95% CI 0.86, 0.88], P < 0.001). Even when FDG uptake was low, ViT produced an AUC of 0.81 [95% CI 0.77, 0.85], which was higher than that of the CNN (DenseNet, 0.65 [95% CI 0.59, 0.70], P < 0.001). We demonstrated the clinical value of ViT by showing its sensitive analysis of easy-to-miss cases of oncological diseases.
More Related Videos
09:55Radiosynthesis, Quality Control, and Small Animal Positron Emission Tomography Imaging of 68Ga-Labelled Nano Molecules
Published on: October 4, 2024
08:55A Practical Guide for the Production and PET/CT Imaging of 68Ga-DOTATATE for Neuroendocrine Tumors in Daily Clinical Practice
Published on: April 17, 2019
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
![Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F3777.jpg&w=3840&q=50)