Correction: Time-, space- and energy-resolved in situ characterization of catalysts by X-ray absorption spectroscopy

Stefan Peters1, Benny Kunkel1, Cafer Tufan Cakir2

  • 1Leibniz Institute for Catalysis (LIKAT Rostock), Albert-Einstein-Str. 29a, Rostock 18059, Germany. sebastian.wohlrab@catalysis.de.

Chemical Communications (Cambridge, England)
|April 11, 2024
PubMed

Related Concept Videos

Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
2.1K
Atomic Absorption Spectroscopy: Atomization Methods01:25

Atomic Absorption Spectroscopy: Atomization Methods

Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
1.8K
Atomic Absorption Spectroscopy: Interference01:25

Atomic Absorption Spectroscopy: Interference

Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
2.3K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
1.1K
Heterogeneous Catalysis01:22

Heterogeneous Catalysis

Heterogeneous catalysis involves a catalyst in a different phase from the reactants. It is a process where the catalyst and the reactants are in distinct phases, typically solid and gas or liquid.Most heterogeneous catalysts are metals, metal oxides, or acids. The list includes transition metals like iron (Fe), cobalt (Co), nickel (Ni), palladium (Pd), platinum (Pt), chromium (Cr), manganese (Mn), tungsten (W), silver (Ag), and copper (Cu). These metals possess partially vacant d orbitals that...
141