High-Resolution Cardiac Positron Emission Tomography/Computed Tomography for Small Animals
Published on: December 16, 2022
Learned high-resolution cardiac CT imaging from ultra-high-resolution PCD-CT
Emily K Koons1,2, Hao Gong1, Andrew Missert1,2
1Department of Radiology, Mayo Clinic, Rochester, MN, USA 55905.
Abstract:
Coronary computed tomography angiography (cCTA) is a widely used non-invasive diagnostic exam for patients with coronary artery disease (CAD). However, most clinical CT scanners are limited in spatial resolution from use of energy-integrating detectors (EIDs). Radiological evaluation of CAD is challenging, as coronary arteries are small (3-4 mm diameter) and calcifications within them are highly attenuating, leading to blooming artifacts. As such, this is a task well suited for high spatial resolution. Recently, photon-counting-detector (PCD) CT became commercially available, allowing for ultra-high resolution (UHR) data acquisition. However, PCD-CTs are costly, restricting widespread accessibility. To address this problem, we propose a super resolution convolutional neural network (CNN): ILUMENATE (Improved LUMEN visualization through Artificial super-resoluTion imagEs), creating a high resolution (HR) image simulating UHR PCD-CT. The network was trained and validated using patches extracted from 8 patients with a modified U-Net architecture. Training input and labels consisted of UHR PCD-CT images reconstructed with a smooth kernel degrading resolution (LR input) and sharp kernel (HR label). The network learned the resolution difference and was tested on 5 unseen LR patients. We evaluated network performance quantitatively and qualitatively through visual inspection, line profiles to assess spatial resolution improvements, ROIs for CT number stability and noise assessment, structural similarity index (SSIM), and percent diameter luminal stenosis. Overall, ILUMENATE improved images quantitatively and qualitatively, creating sharper edges more closely resembling reconstructed HR reference images, maintained stable CT numbers with less than 4% difference, reduced noise by 28%, maintained structural similarity (average SSIM = 0.70), and reduced percent diameter stenosis with respect to input images. ILUMENATE demonstrates potential impact for CAD patient management, improving the quality of LR CT images bringing them closer to UHR PCD-CT images.
More Related Videos
05:32Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
Published on: February 21, 2025
12:15Tissue Preparation Techniques for Contrast-Enhanced Micro Computed Tomography Imaging of Large Mammalian Cardiac Models with Chronic Disease
Published on: February 8, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...