Experimental Study on Dynamic Characteristics of Damaged Post-Tensioning Concrete Sleepers Using Impact Hammer
Jung-Youl Choi1, Tae-Hyung Shin2, Sun-Hee Kim3
1Department of Construction Engineering, Dongyang University, No. 145 Dongyangdae-ro, Punggi-eup, Yeongju-si 36040, Gyeongsangbuk-do, Republic of Korea.
Abstract:
Concrete sleepers in operation are commonly damaged by various internal and external factors, such as poor materials, manufacturing defects, poor construction, environmental factors, and repeated loads and driving characteristics of trains; these factors affect the vibration response, mode shape, and natural frequency of damaged concrete sleepers. However, current standards in South Korea require only a subjective visual inspection of concrete sleepers to determine the damage degree and necessity of repair or replacement. In this study, an impact hammer test was performed on concrete sleepers installed on the operating lines of urban railroads to assess the field applicability of the modal test method, with the results indicating that the natural frequency due to concrete sleeper damage was lower than that of the undamaged state. Furthermore, the discrepancy between the simulated and measured natural frequencies of the undamaged concrete sleeper was approximately 1.87%, validating the numerical analysis result. The natural frequency of the damaged concrete sleepers was lower than that of the undamaged concrete sleeper, and cracks in both the concrete sleeper core and the rail seat had the lowest natural frequency among all the damage categories. Therefore, the damage degrees of concrete sleepers can be quantitatively estimated using measured natural-frequency values.
More Related Videos
Related Concept Videos
Non-destructive Tests for Concrete Strength
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
Impact Strength of Concrete
Microcracking in Concrete
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Fatigue Strength of Concrete