Published on: February 25, 2022
Pressure Infusor Assisted Arthrocentesis
Salih Oflioğlu1, Anıl Özyurt2, Candan Efeoğlu3
1Resident in Oral and Maxillofacial Surgery, Dokuz Eylül University, Faculty of Dentistry, Department of Oral and Maxillofacial Surgery, Sağlık ve Sanat Yerleşkesi, İzmir.
This study introduces a modified temporomandibular joint arthrocentesis technique using a pressure infusion cuff for improved irrigation. This method enhances physician comfort and patient compliance during minimally invasive TMJ disorder treatments.
Area of Science:
- Oral and Maxillofacial Surgery
- Orthodontics
- Biomedical Engineering
Background:
- Temporomandibular joint (TMJ) internal disorders often cause limited mouth opening and pain.
- Treatment strategies vary from conservative to surgical interventions.
- Current arthrocentesis techniques may lead to operator fatigue and inconsistent irrigation flow.
Purpose of the Study:
- To introduce a novel modification to arthrocentesis for TMJ internal disorders.
- To utilize a pressure infusion cuff for enhanced irrigation control and operator comfort.
- To improve patient compliance and enable quantitative data collection.
Main Methods:
- A pressure infusion cuff (VBM Classic Infusor) was adapted for TMJ arthrocentesis irrigation.
- The cuff system replaced traditional syringes or peristaltic pumps for fluid delivery.
- Continuous pressure monitoring via the cuff's integrated sphygmomanometer was employed.
Main Results:
- The pressure infusion cuff provided stable and efficient irrigation flow throughout the procedure.
- The technique reduced operator hand and wrist strain associated with manual irrigation.
- Pressure monitoring allowed for real-time adjustments, enhancing patient comfort and compliance.
Conclusions:
- The modified arthrocentesis technique using a pressure infusion cuff offers a viable alternative for TMJ internal disorder treatment.
- This method improves procedural efficiency, operator ergonomics, and patient experience.
- The system facilitates objective pressure monitoring, beneficial for clinical studies and data acquisition.