Related Experiment Video
Updated: Jun 28, 2025

Author Spotlight: Investigating the Impact of Emotional Prosodies on Voice Recognition and Perception
Published on: August 9, 2024
Improved recovery of cardiac auscultation sounds using modified cosine transform and LSTM-based masking
Awad Al-Zaben1,2, Amjad Al-Fahoum3, Muhannad Ababneh4
1Biomedical Engineering Department, Engineering Faculty, Hashemite University, Zarqa, Jordan. azaben@yu.edu.jo.
Abstract:
Obtaining accurate cardiac auscultation signals, including basic heart sounds (S1 and S2) and subtle signs of disease, is crucial for improving cardiac diagnoses and making the most of telehealth. This research paper introduces an innovative approach that utilizes a modified cosine transform (MCT) and a masking strategy based on long short-term memory (LSTM) to effectively distinguish heart sounds and murmurs from background noise and interfering sounds. The MCT is used to capture the repeated pattern of the heart sounds, while the LSTMs are trained to construct masking based on the repeated MCT spectrum. The proposed strategy's performance in maintaining the clinical relevance of heart sounds continues to demonstrate effectiveness, even in environments marked by increased noise and complex disruptions. The present work highlights the clinical significance and reliability of the suggested methodology through in-depth signal visualization and rigorous statistical performance evaluations. In comparative assessments, the proposed approach has demonstrated superior performance compared to recent algorithms, such as LU-Net and PC-DAE. Furthermore, the system's adaptability to various datasets enhances its reliability and practicality. The suggested method is a potential way to improve the accuracy of cardiovascular diagnostics in an era of rapid advancement in medical signal processing. The proposed approach showed an enhancement in the average signal-to-noise ratio (SNR) by 9.6 dB at an input SNR of - 6 dB and by 3.3 dB at an input SNR of 10 dB. The average signal distortion ratio (SDR) achieved across a variety of input SNR values was 8.56 dB.
Related Concept Videos
Assessment of the Cardiovascular System IV: Auscultation
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Heart Sounds
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original...
Cardiovascular System Abnormal Findings II: Auscultation
Abnormal Heart Sounds
Gallops:

