Background:
In the UK National Health Service (NHS), the patient's vital signs are monitored and summarised into a National Early Warning Score (NEWS) score. A set of computer-aided risk scoring systems (CARSS) was developed and validated for predicting in-hospital mortality and sepsis in unplanned admission to hospital using NEWS and routine blood tests results. We sought to assess the accuracy of these models to predict the risk of COVID-19 in unplanned admissions during the first phase of the pandemic.
Methods:
Adult ( > = 18 years) non-elective admissions discharged (alive/deceased) between 11-March-2020 to 13-June-2020 from two acute hospitals with an index NEWS electronically recorded within ± 24 h of admission. We identified COVID-19 admission based on ICD-10 code 'U071' which was determined by COVID-19 swab test results (hospital or community). We assessed the performance of CARSS (CARS_N, CARS_NB, CARM_N, CARM_NB) for predicting the risk of COVID-19 in terms of discrimination (c-statistic) and calibration (graphically).
Results:
The risk of in-hospital mortality following emergency medical admission was 8.4% (500/6444) and 9.6% (620/6444) had a diagnosis of COVID-19. For predicting COVID-19 admissions, the CARS_N model had the highest discrimination 0.73 (0.71 to 0.75) and calibration slope 0.81 (0.72 to 0.89) compared to other CARSS models: CARM_N (discrimination:0.68 (0.66 to 0.70) and calibration slope 0.47 (0.41 to 0.54)), CARM_NB (discrimination:0.68 (0.65 to 0.70) and calibration slope 0.37 (0.31 to 0.43)), and CARS_NB (discrimination:0.68 (0.66 to 0.70) and calibration slope 0.56 (0.47 to 0.64)).
Conclusions:
The CARS_N model is reasonably accurate for predicting the risk of COVID-19. It may be clinically useful as an early warning system at the time of admission especially to triage large numbers of unplanned admissions because it requires no additional data collection and is readily automated.
Related Concept Videos
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast,...
Actuarial Approach
Consider the example of a high-risk surgical procedure with significant early-stage mortality. A two-year clinical study is conducted,...
Statistical Methods for Analyzing Epidemiological Data
Relative Risk
Receiver Operating Characteristic Plot