Related Experiment Video
Updated: Jun 28, 2025

A Teleoperated Robotic System-Assisted Percutaneous Transiliac-Transsacral Screw Fixation Technique
Published on: January 6, 2023
Upper extremity contact pressure measurement in robot-assisted pelvic surgery
Naoki Kimura1,2, Yuta Yamada3, Yuji Hakozaki2
1Department of Urology, National Center for Global Health and Medicine, Shinjuku-ku, Tokyo, Japan.
Abstract:
Upper extremity complications are often a problem in robot-assisted pelvic surgery (RAPS) with the lithotomy-Trendelenburg position (LT-position). This study focused on upper extremity contact pressure (UEP) and examined the relationship between UEP and upper extremity complications. From May 2020 to April 2022 at the University of Tokyo Hospital, UEP was measured in 155 patients undergoing RARP and 20 patients undergoing RARC. A total of 350 sets of UEP were investigated in this study. UEP was measured using a portable interface pressure sensor (Palm Q, Cape CO., Kanagawa, Japan) in the preoperative lithotripsy position (L-position), preoperative LT-position, and postoperative L-position. UEP was increased in the preoperative LT-position than in the preoperative L-position (right side 5.2 mmHg vs. 17.1 mmHg, left side 5.3 mmHg vs. 17.1 mmHg, P < 0.001, respectively), and was decreased in the postoperative L-position than in preoperative LT-position (right side 17.1 mmHg vs. 10.8 mmHg, left side 17.1 mmHg vs. 10.6 mmHg, P < 0.001, respectively). Eleven upper extremities developed shoulder pain. UEP of the preoperative LT-position tended to be higher in the upper extremity exhibiting shoulder pain (25.6 mmHg (15.4-30.3) vs. 17.1 mmHg (12.0-24.4) P = 0.0901). UEP measurements may help prevent postoperative shoulder pain.