Related Experiment Video
Updated: May 5, 2026

Transcatheter Pulmonary Valve Replacement from Autologous Pericardium with a Self-Expandable Nitinol Stent in an Adult Sheep Model
Published on: June 8, 2022
Endovascular retrieval of a migrated covered stent from the pulmonary artery
Ziga Cizman1, William Zachery Paden1, Tyler Smith1
1Department of Interventional Radiology, University of Utah School of Medicine, 50 N Medical Dr, Salt Lake City, UT 84132, USA.
Abstract:
Stent migration is a rare but significant complication following endovascular procedures. Techniques for managing dislodged stents have included surgical, endovascular, and conservative approaches. This case details a patient who had a covered stent placed within the left renal vein which later migrated to the pulmonary artery causing damage to the tricuspid valve. The migrated stent was successfully removed using a percutaneous endovascular approach utilizing fluoroscopy and transesophageal echocardiogram guidance.
More Related Videos
08:12Fully Endoscopic Mitral Valve Repair with Percutaneous Cannulation of Groin Vessels
Published on: May 26, 2023
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
Related Concept Videos
Venous Thrombosis III: Interprofessional Care
Pulmonary Embolism II: Diagnostic Studies and Interprofessional Care