Related Experiment Video
Updated: Jun 28, 2025

Author Spotlight: Advancing Awake Nasotracheal Intubation with Flexible Video Rhino-Laryngoscopes
Published on: August 2, 2024
Comparative Evaluation of Linscope and King Vision Video Laryngoscopes in Tracheal Intubation: A Randomized
Mohd Luqman1, S Moied Ahmed2, Amal Shaharyar3
1Cardiac Anesthesia, Fortis Hospital Mohali, Mohali, IND.
Abstract:
Introduction Indirect laryngoscopy has become a widely accepted method for learning the techniques of airway management. The incorporation of small, less expensive, and yet more reliable video cameras in laryngoscopes has given the process of laryngoscopy and intubation a big leap. The King Vision video laryngoscope (Medline Industries, USA) has demonstrated promise in several settings while the Linscope video laryngoscope (Centrum, Turkey) is a newly launched device and no literature is available to the best of our knowledge. Therefore, we aimed to compare the performance of the Linscope video laryngoscope (VL) and King Vision video laryngoscope. Method This is a randomized controlled trial study. Seventy patients, after approval from the institute's ethical clearance, were divided into two groups. In Group A, patients were intubated with Linscope VL and in Group B patients were intubated with King Vision VL as per the protocol. The primary outcome measure was the duration of tracheal intubation. Secondary outcomes were measured by the number of attempts, ease of intubation, and glottic view. Results Both Linscope VL and King Vision VL groups were comparable in terms of mean intubation time (20.34 s vs. 19.45 s). The endotracheal intubation with both devices was 100% successful at the first attempt. Both the devices provided a percentage of glottic opening (POGO) score of > 70% and a clear vision of the glottis. The POGO score obtained with King Vision VL was 83.57 ± 11.41% and with Linscope VL was 87.85 ± 10.31%. POGO score was greater with Linscope VL compared to King Vision VL, but the difference was not statistically significant (p-value>0.05). Conclusion King Vision demonstrated shorter intubation time and fewer optimization maneuvers. Both devices achieved a 100% success rate on the first attempt. While both devices are viable first-line options, King Vision's well-established efficacy in the literature suggests its preference over Linscope till extensive evidence is available in the future.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Tracheostomy Suctioning I: Pre-Procedural Steps
Equipment Required
First, gather all necessary equipment: a sterile suction catheter, a sterile disposable container, sterile gloves, a towel or...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Tracheostomy Suctioning II: Procedure

