Related Experiment Video
Updated: Jun 28, 2025

Exploring the Effects of Atmospheric Forcings on Evaporation: Experimental Integration of the Atmospheric Boundary Layer and Shallow Subsurface
Published on: June 8, 2015
Design of a hemispherical shell shaped natural ventilation temperature observation instrument
Zilan Ma1, Jie Yang1, Lixia Jiang1
1Jiangsu Collaborative Innovation Center on Atmospheric Environment and Equipment Technology, Nanjing University of Information Science and Technology, 210044 Nanjing, China.
Abstract:
Atmospheric temperature is fundamental information for various industries, such as production, life, and scientific research. The temperature error induced by the solar rays can reach 1 °C or even higher. A hemispherical shell-shaped atmospheric temperature measuring instrument that can reduce heat pollution and increase air velocity was designed. First, the instrument was optimized using computational fluid dynamics (CFD) software packages. Then, the CFD software packages were employed to quantify the temperature errors of the instrument with varying situations. A neural network model was employed to develop a temperature error correction model that can be targeted for multi-variable changes. This model provides accurate correction data when the influencing factors change continuously. Finally, field experiments were performed. The experimental data analysis indicates that the mean temperature error and the maximum error of the instrument before correction are 0.08 and 0.25 °C, respectively. The root mean square error, the mean absolute error, and the correlation coefficient between measured temperature errors from experiments and corrected temperature errors from the correction model are 0.099, 0.016, and 0.952 °C, respectively. By utilizing a temperature error correction model, the measuring error of the instrument can be minimized to a range between -0.05 and 0.04 °C. Consequently, the instrument is anticipated to enhance temperature measurement accuracy to ∼0.1 °C.
More Related Videos
05:56Construction of a Compact Low-Cost Radiation Shield for Air-Temperature Sensors in Ecological Field Studies
Published on: November 6, 2018
09:55Surface Renewal: An Advanced Micrometeorological Method for Measuring and Processing Field-Scale Energy Flux Density Data
Published on: December 12, 2013
Related Concept Videos
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Design Example: Calculating Safe Diameter for Wind-Exposed Disc
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...