Related Experiment Video
Updated: Jun 28, 2025

Rapid Point-of-Care Assay of Enoxaparin Anticoagulant Efficacy in Whole Blood
Published on: October 12, 2012
Challenges to Laboratory Monitoring of Direct Oral Anticoagulants
1Irvine Department of Pathology and Laboratory Medicine, University of California, Orange, CA, USA.
Abstract:
Direct oral anticoagulants (DOACs) exert anticoagulation effect by directly inhibiting Factor Xa (rivaroxaban, apixaban, and edoxaban) or thrombin (dabigatran). Though DOACs are characterized by fixed-dose prescribing and generally do not require routine laboratory drug-level monitoring (DLM), circumstances may arise where the DLM may aid in clinical decision-making, including DOAC dose adjustment, anticoagulant class change, or decisions to withhold or administer reversal agents. We review the current literature that describes high-risk patient groups in which DLM may be beneficial for improved patient anticoagulation management and stewardship. The review also summarizes the limitations of conventional coagulation testing and discuss the emerging utility of quantitative methods for routine and rapid emergent evaluation of DOAC drug levels-in particular, the Anti-Xa activity to detect Factor Xa Inhibitors (rivaroxaban, apixaban, and edoxaban). Both technical and regulatory barriers to widespread DLM implementation are limiting factors to further clinical research that must be overcome, in order to propose universal DOAC DLM strategies and provide clinical-laboratory correlation to formally classify high-risk patient groups.
Related Concept Videos
Anticoagulant Drugs: Vitamin K Antagonists and Direct Oral Anticoagulants
Warfarin, a prominent vitamin K antagonist family member, exerts its effect by inhibiting the enzyme VKORC1 (vitamin K epoxide reductase complex 1). By hindering this enzyme, warfarin...
Anticoagulant Drugs: Low-Molecular-Weight Heparins
EDTA: Indirect and Alkalimetric Titration
EDTA: Direct, Back-, and Displacement Titration
Direct titration involves buffering the metal ion solution to the desired pH and directly titrating with standard EDTA until the endpoint. The optimum pH ensures a large conditional formation constant of metal−EDTA and visibility of the free indicator color in the solution. In addition, auxiliary complexing reagents are used to prevent the precipitation of metal hydroxides...
Drug Concentrations: Measurements
Plasma...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...