Related Experiment Video
Updated: Jun 28, 2025

07:34
Fetal Mouse Cardiovascular Imaging Using a High-frequency Ultrasound 30/45MHZ System
Published on: May 5, 2018
11.6K
Doppler in High-Risk Pregnancy and Its Correlation With Feto-Maternal Outcomes: A Prospective Study
1Obstetrics and Gynaecology, Maharaja Agrasen Medical College, Agroha, Hisar, IND.
Cureus
|April 23, 2024
Summary
Abnormal antenatal Doppler findings in high-risk pregnancies are linked to increased low birth weight and neonatal intensive care unit (NICU) admissions. Doppler ultrasound aids in planning delivery and predicting newborn outcomes.
Area of Science:
- Obstetrics and Gynecology
- Fetal Medicine
- Diagnostic Imaging
Background:
- Fetal growth monitoring using Doppler ultrasound is crucial for identifying high-risk pregnancies.
- Doppler studies provide non-invasive hemodynamic information, aiding in the assessment of fetal compromise.
- Timely intervention in high-risk pregnancies improves perinatal outcomes.
Purpose of the Study:
- To correlate antenatal Doppler findings with perinatal outcomes.
- To assess the relationship between Doppler findings and preterm labor, cesarean section, birth weight, and NICU admission.
- To establish NICU admission as the primary outcome measure.
Main Methods:
- Prospective study of 100 high-risk pregnant women.
- Inclusion criteria: oligohydramnios, IUGR, PIH, DM, anemia, Rh incompatibility.
- Doppler assessment of umbilical artery, MCA, and uterine arteries; correlation with delivery and fetal outcomes.
Main Results:
- Abnormal Doppler findings were prevalent in PIH, IUGR, and oligohydramnios with IUGR.
- Abnormal Doppler was significantly associated with low birth weight (93.75%) and NICU admissions (81.25%).
- No significant effect of abnormal Doppler on preterm delivery or cesarean section rates was observed.
Conclusions:
- Abnormal Doppler studies in pregnancy correlate with adverse neonatal outcomes like low birth weight and NICU admission.
- Doppler ultrasound is a valuable tool for planning delivery mode and anticipating neonatal care needs.
- The findings support the use of Doppler studies for risk assessment and management in high-risk pregnancies.
Related Concept Videos
Assessing Blood pressure using a doppler ultrasound
1.3K
To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
1.3K
Ultrasonography
4.5K
Ultrasonography is an imaging technique that uses high-frequency sound waves to visualize the body's internal structures. It is a non-invasive and safe procedure that does not involve the use of ionizing radiation, making it widely used in various medical fields. Ultrasonography is used to study heart function, blood flow in the neck or extremities, certain conditions such as gallbladder disease, and fetal growth and development.
During an ultrasonography procedure, a handheld device called...
During an ultrasonography procedure, a handheld device called...
4.5K
Equipments Used To Measure Blood Pressure
964
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
964

