1GS Eye Clinic (Y.K.), Seoul, Korea; Department of Ophthalmology (S.B.H., S.-A.C., Y.W.L.), Kangwon National University Hospital, Kangwon National University School of Medicine, Chuncheon, Korea; Department of Ophthalmology (K.K.), Kim's Eye Hospital, Konyang University College of Medicine, Seoul, Korea; and Department of Ophthalmology (S.Y.H., C.Y.C.), Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea.
Objective:
To evaluate the effects of rigid corneal lenses (RCL) in patients with keratoconus, based on eccentricity.
Methods:
Eighty-four eyes from 84 patients were included in this retrospective comparative study. Based on the median value of eccentricity difference between the cornea and back surface of the RCL, the patients were divided into groups 1 (<0.08) and 2 (≥0.08). Visual acuity, refractive index, and corneal topography indices were compared before and three months after lens use.
Results:
Visual acuity, astigmatism, refractive error, corneal curvature, and corneal thickness improved significantly in both groups. Apical power and anterior elevation improved significantly in group 1, with small differences in eccentricity, but not in group 2. Changes in apical power before and after lens use were significantly different between the two groups.
Conclusion:
The RCL was effective for the cornea of keratoconus, especially when the prescription was made with a small difference in eccentricity.
More Related Videos
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024
05:56Scleral Cross-linking Using Riboflavin and Ultraviolet-A Radiation for Prevention of Axial Myopia in a Rabbit Model
Published on: April 3, 2016
Related Concept Videos
Focusing of Light in the Eye
Angle Closure Glaucoma: Treatment
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Eccentric Axial Loading in a Plane of Symmetry
Design of Columns under an Eccentric Load
General Case of Eccentric Axial Loading
Consider a member subjected to equal and opposite forces that are applied along a line that does not coincide with the member's neutral axis. In unsymmetrical...