Utility of RAND/UCLA appropriateness method in validating multiple-choice questions on ECG
Tomohiro Kaga1, Shinji Inaba2, Yukari Shikano3
1Ehime University, Toon, Japan.
Objectives:
This study aimed to investigate the utility of the RAND/UCLA appropriateness method (RAM) in validating expert consensus-based multiple-choice questions (MCQs) on electrocardiogram (ECG).
Methods:
According to the RAM user's manual, nine panelists comprising various experts who routinely handle ECGs were asked to reach a consensus in three phases: a preparatory phase (round 0), an online test phase (round 1), and a face-to-face expert panel meeting (round 2). In round 0, the objectives and future timeline of the study were elucidated to the nine expert panelists with a summary of relevant literature. In round 1, 100 ECG questions prepared by two skilled cardiologists were answered, and the success rate was calculated by dividing the number of correct answers by 9. Furthermore, the questions were stratified into "Appropriate," "Discussion," or "Inappropriate" according to the median score and interquartile range (IQR) of appropriateness rating by nine panelists. In round 2, the validity of the 100 ECG questions was discussed in an expert panel meeting according to the results of round 1 and finally reassessed as "Appropriate," "Candidate," "Revision," and "Defer."
Results:
In round 1 results, the average success rate of the nine experts was 0.89. Using the median score and IQR, 54 questions were classified as " Discussion." In the expert panel meeting in round 2, 23% of the original 100 questions was ultimately deemed inappropriate, although they had been prepared by two skilled cardiologists. Most of the 46 questions categorized as "Appropriate" using the median score and IQR in round 1 were considered "Appropriate" even after round 2 (44/46, 95.7%).
Conclusions:
The use of the median score and IQR allowed for a more objective determination of question validity. The RAM may help select appropriate questions, contributing to the preparation of higher-quality tests.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
ECG Interpretation of Rhythms
Components of the Electrocardiogram
The primary components of a normal ECG waveform in Normal sinus rhythm(NSR) include the P wave, PR interval, QRS complex, ST segment, T wave, and occasionally a U wave.
ECG waveforms are divided by vertical and horizontal lines at standard intervals.
The horizontal axis measures time and rate, and the vertical axis measures amplitude or voltage....
Cochran's Q Test