Related Experiment Video
Updated: Jul 29, 2026

Analysis of Fucosylated Human Milk Trisaccharides in Biotechnological Context Using Genetically Encoded Biosensors
Published on: April 13, 2019
Determination of moxifloxacin in milk using a ratiometric fluorescent sensor based on Ag-MOF@curcumin
Jiaxing Zhao1, Kedan Wang2, Yu Song2
1College of Chemistry and Materials Science, Sichuan Normal University Chengdu 610068 Sichuan China.
Abstract:
Moxifloxacin (MFX) has attracted increasing public concern recently, and the development of a simple and effective analysis method has become a research focus. In this work, a simple, sensitive and ratiometric fluorescent sensor based on Ag-MOF@curcumin was designed and investigated. Ag-MOF@curcumin displays emission at 410 nm and 475 nm under excitation at 330 nm. When MFX is added, a new emission peak appears at 500 nm, and the F500/F410 ratio has a linear relationship with the MFX concentration in the range 0-35 μmol L-1 with a low LOD (0.179 μmol L-1). Finally, the developed sensor was used for the determination of MFX in milk. This work provides an excellent fluorescent sensor for highly selective and rapid detection of MFX residues.