Alerts to improve occupational protection during Interventional Radiology. More attention is needed for simple but
Eliseo Vano1, Roberto M Sanchez Casanueva1, Jose M Fernandez Soto1
1Instituto de Investigación Sanitaria del Hospital Clínico San Carlos and Medical Physics Service, Madrid, Spain; Department of Radiology, Medical School. Complutense University, Madrid, Spain.
Abstract:
Occupational protection could be improved in interventional radiology. The monthly personal dosimetry cannot alert on some occupational doses with anomalous values for certain procedures. Active electronic personal dosimeters linked wireless to a dose management system (DMS), allow for the measurement of occupational doses per procedure, integrating this information with patient dose indicators and with technical and geometrical conditions of the procedures. We analysed around 3100 occupational dose values for individual procedures collected during the last two years, in an interventional radiology laboratory of a University Hospital and two groups, with patient doses higher than 100 Gy.cm2, and lower than 30 Gy.cm2. An unshielded reference dosimeter located at the C-arm registers the ambient dose equivalent (ADE) per procedure to be compared with the personal dose equivalent (PDE) over the apron. The ratio between both values PDE/ADE is a good indication of occupational protection. Alerts for occupational protection optimisation are suggested. For the full sample, 8.4 % of occupational doses measured over the protective apron of the interventionists were higher than 100 µSv and 3.8 % higher than 200 µSv per procedure. Occupational protection for complex procedures (>100 Gy.cm2) had median values of 46 µSv for PDE and 3.3 % for PDE/ADE. However, for simple procedures, (<30 Gy.cm2) the median values were 10 µSv and 28.4 %. This last percentage is 9 times higher than the value for complex procedures. This lack of protection should be corrected and the need to reduce some occupational doses reinforced in radiation protection training programmes for interventionists.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Radiological Investigation I: X-ray and CT
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Personal Protective Equipment