Related Experiment Video
Updated: Jun 27, 2025

High-throughput and Comprehensive Drug Surveillance Using Multisegment Injection-Capillary Electrophoresis-Mass Spectrometry
Published on: April 23, 2019
Quantification of Etoricoxib in Low Plasma Volume by UPLC-PDA and Application to Preclinical Pharmacokinetic Study
Sapir Ifrah1, Daniel Porat1, Mordechai Deutsch2
1Department of Clinical Pharmacology, School of Pharmacy, Faculty of Health Sciences, Ben-Gurion University of the Negev, Beer-Sheva 8410501, Israel.
Abstract:
An ultra-performance liquid chromatography with photodiode array (UPLC-PDA) UV detection method was developed here for the first time for simple, rapid, selective and sensitive quantification of the commonly prescribed selective cyclooxygenase-2 (COX-2) inhibitor etoricoxib in low plasma volumes (50 μL). The method includes protein precipitation followed by liquid-liquid extraction, evaporation and reconstitution. A gradient mobile phase of 75:25 going to 55:45 (v/v) water:acetonitrile (1 mL/min flow rate) was applied. Total run time was 8 min, representing a significant improvement relative to previous reports. Excellent linearity (r2 = 1) was obtained over a wide (0.1-12 µg/mL) etoricoxib concentration range. Short retention times for etoricoxib (4.9 min) and the internal standard trazodone (6.4 min), as well as high stability, recovery, accuracy, precision and reproducibility, and low etoricoxib LOD (20 ng/mL) and LOQ (100 ng/mL), were achieved. Finally, the method was successfully applied to a pharmacokinetic study (single 20 mg/kg orally administered etoricoxib mini-capsule) in rats. In conclusion, the advantages demonstrated in this work make this analytical method both time- and cost-efficient for drug monitoring in pre-clinical/clinical settings.
More Related Videos
08:57Sample Extraction and Simultaneous Chromatographic Quantitation of Doxorubicin and Mitomycin C Following Drug Combination Delivery in Nanoparticles to Tumor-bearing Mice
Published on: October 5, 2017
08:38Quantification of the Immunosuppressant Tacrolimus on Dried Blood Spots Using LC-MS/MS
Published on: November 8, 2015
Related Concept Videos
Noncompartmental Analysis: Miscellaneous Pharmacokinetic Parameters
One key aspect of the noncompartmental approach is determining a drug's total clearance. This can be done by dividing the drug dose by the area under the concentration-time curve from zero to infinity. The area under the concentration-time curve represents the drug's...
One-Compartment Open Model for IV Bolus Administration: Estimation of Elimination Rate Constant, Half-Life and Volume of Distribution
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
One-Compartment Open Model for IV Bolus Administration: Estimation of Clearance
In the one-compartment open model for intravenous (IV) bolus administration, clearance is estimated by dividing the elimination rate by the plasma drug concentration. This equation leverages the elimination rate constant and the apparent...
One-Compartment Open Model: Wagner-Nelson and Loo Riegelman Method for ka Estimation
On...
Volume of Distribution