Purpose:
Osteoporosis is a pressing public health concern among older adults, contributing to substantial mortality and morbidity rates. Low- to middle-income countries (LMICs) often grapple with limited access to dual-energy X-ray absorptiometry (DXA), the gold standard for early osteoporosis detection. This study aims to assess the performance of the FRAX® score as a population-wide screening tool for predicting osteoporosis risk, rather than fracture, in individuals aged 50 and above within an LMIC context.
Methods:
This retrospective cohort study (n=864) assessed the performance of the FRAX® score for predicting osteoporosis risk using comparative c-statistics from Receiver Operating Characteristic (ROC) curves. Hazard ratios (HR) and 95 % confidence intervals (CI) were calculated, with p-values <0.05 indicating statistically significant.
Results:
The 10-year FRAX® probability for hip fracture, calculated without bone mass density (BMD), exhibited significantly superior performance compared to the 10-year FRAX® probability for major fracture in predicting osteoporosis risk (AUROC: 0.71 versus 0.67, p<0.001). Within 2 to 10 years of follow-up, the 10-year FRAX® probability for hip fracture showed both greater predictive performance and net benefit in the decision curve compared to the FRAX® 10-year probability for major fracture. A newly established cutoff of 1.9 % yielded a negative predictive value of 92.9 % (95 %CI: 90.4-94.8 %) for the 10-year FRAX® probability for hip fracture.
Conclusion:
The 10-year FRAX® probability for hip fracture estimated without BMD emerges as an effective 10-year screening tool for identifying osteoporosis risk in aged 50 and older, especially when confronted with limited access to DXA scans in LMICs.
Mini Abstract:
The Fracture Risk Assessment Tool score performance as an osteoporosis screening tool was assessed in areas with limited dual-energy X-ray access. The hip fracture probability showed better performance than major fracture probability within 2 to 10 years. The tool emerges as effective for screening osteoporosis risk in individuals over 50.
More Related Videos
07:12Semiautomated Longitudinal Microcomputed Tomography-based Quantitative Structural Analysis of a Nude Rat Osteoporosis-related Vertebral Fracture Model
Published on: September 28, 2017
04:00Author Spotlight: Assessing Surgical Frailty with Point-of-Care Ultrasound of Quadriceps Muscles
Published on: July 26, 2024
Related Concept Videos
Bone Disorders
Bone deposition is also affected by the levels of sex hormones like estrogen and testosterone that promote osteoblast activity and bone matrix synthesis. When the level of these hormones decreases due to aging, it causes a reduction in bone deposition. As a result, bone resorption by osteoclasts...
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the...