Related Experiment Video
Updated: Jun 27, 2025

A Model to Simulate Clinically Relevant Hypoxia in Humans
Published on: December 22, 2016
U-shaped relationship between lights-out time and nocturnal oxygen saturation during the first trimester: An analysis
Hongxu Chen1, Danyang Zhao2, Zixuan Guo2
1School of Public Health, Xinjiang Medical University, Urumqi, 830063, China.
Objective:
Preventing adverse events due to unstable oxygen saturation (SpO2) at night in pregnant women is of utmost importance. Poor sleep has been demonstrated to impact SpO2 levels. Nowadays, many gravida have a habit of prolonged exposure to light before sleep, which can disrupt their sleep. Therefore, this study aimed at investigate the relationship between lights-out time, sleep parameters and SpO2, exploring the underlying mechanisms.
Methods:
The data of 2881 eligible subjects from the Nulliparous Pregnancy Outcomes Study Monitoring Mothers-to-be and Sleep Disordered Breathing (nuMOM2b-SDB) database were analyzed. Multiple linear regression models were used to investigate the relationship between lights-out time and SpO2. In addition, restricted cubic splines (RCS) were employed to fit the nonlinear correlation between the two variables. The smoothing curve method was further utilized to depict the relationship between lights-out time and SpO2 based on various subgroup variables.
Results:
All participants were categorized according to race/ethnicity. A negative correlation was observed between nighttime lights-out time and average value of SpO2 (Avg-SpO2) (β = -0.05, p = 0.010). RCS revealed a U-shaped relationship between lights-out time and Avg-SpO2, with the turning point at 22:00. The subcomponent stratification results indicated that the Avg-SpO2 and minimum value of SpO2(Min-SpO2) of advanced maternal age decreased as the lights-out time was delayed. Furthermore, overweight and obese gravida showed lower Avg-SpO2 and Min-SpO2 levels than normal weight.
Conclusions:
A U-shaped relationship was identified between lights-out time and nocturnal Avg-SpO2 during early pregnancy, with the inflection at 22:00. Notably, later lights-out times are associated with lower levels of Min-SpO2 for advanced maternal age. The findings suggest that appropriately adjusting the duration of light exposure before sleep and maintaining a relatively restful state may be more beneficial for the stability of SpO2 in pregnant women. Conversely, deviations from these practices could potentially lead to pathological alterations in SpO2 levels.
More Related Videos
07:27How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.