Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Non-invasive pulse arrival time as a surrogate for oscillometric systolic blood pressure changes during
Bernhard Hametner1, Severin Maurer2, Alina Sehnert3
1AIT Austrian Institute of Technology GmbH, Center for Health & Bioresources, Medical Signal Analysis, Vienna, Austria.
Abstract:
Background.Non-invasive continuous blood pressure (BP) monitoring is of longstanding interest in various cardiovascular scenarios. In this context, pulse arrival time (PAT), i.e., a surrogate parameter for systolic BP (change), became very popular recently, especially in the context of cuffless BP measurement and dedicated lifestyle interventions. Nevertheless, there is also understandable doubt on its reliability in uncontrolled and mobile settings.Objective.The aim of this work is therefore the investigation whether PAT follows oscillometric systolic BP readings during moderate interventions by physical or mental activity using a medical grade handheld device for non-invasive PAT assessment.Approach.A study was conducted featuring an experimental group performing a physical and a mental task, and a control group. Oscillometric BP and PAT were assessed at baseline and after each intervention. Interventions were selected randomly but then performed sequentially in a counterbalanced order. Multivariate analyses of variance were used to test within-subject and between-subject effects for the dependent variables, followed by univariate analyses for post-hoc testing. Furthermore, correlation analysis was performed to assess the association of intervention effects between BP and PAT.Mainresults.The study included 51 subjects (31 females). Multivariate analysis of variances showed that effects in BP, heart rate, PAT and pulse wave parameters were consistent and significantly different between experimental and control groups. After physical activity, heart rate and systolic BP increased significantly whereas PAT decreased significantly. Mental activity leads to a decrease in systolic BP at stable heart rate. Pulse wave parameters follow accordingly by an increase of PAT and mainly unchanged pulse wave analysis features due to constant heart rate. Finally, also the control group behaviour was accurately registered by the PAT method compared to oscillometric cuff. Correlation analyses revealed significant negative associations between changes of systolic BP and changes of PAT from baseline to the physical task (-0.33 [-0.63, 0.01],p< 0.048), and from physical to mental task (-0.51 [-0.77, -0.14],p= 0.001), but not for baseline to mental task (-0.12 [-0,43,0,20],p= 0.50) in the experimental group.Significance.PAT and the used digital, handheld device proved to register changes in BP and heart rate reliably compared to oscillometric measurements during intervention. Therefore, it might add benefit to future mobile health solutions to support BP management by tracking relative, not absolute, BP changes during non-pharmacological interventions.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...