Related Experiment Video
Updated: Jun 27, 2025

A Novel Digital Platform for a Monitored Home-based Cardiac Rehabilitation Program
Published on: April 19, 2019
Wearable wireless continuous vital signs monitoring on the general ward
Jobbe Pl Leenen1,2, Lisette Schoonhoven3,4, Gijs A Patijn1,5
1Connected Care Centre, Isala, Zwolle.
Purpose Of Review:
Wearable wireless sensors for continuous vital signs monitoring (CVSM) offer the potential for early identification of patient deterioration, especially in low-intensity care settings like general wards. This study aims to review advances in wearable CVSM - with a focus on the general ward - highlighting the technological characteristics of CVSM systems, user perspectives and impact on patient outcomes by exploring recent evidence.
Recent Findings:
The accuracy of wearable sensors measuring vital signs exhibits variability, especially notable in ambulatory patients within hospital settings, and standard validation protocols are lacking. Usability of CMVS systems is critical for nurses and patients, highlighting the need for easy-to-use wearable sensors, and expansion of the number of measured vital signs. Current software systems lack integration with hospital IT infrastructures and workflow automation. Imperative enhancements involve nurse-friendly, less intrusive alarm strategies, and advanced decision support systems. Despite observed reductions in ICU admissions and Rapid Response Team calls, the impact on patient outcomes lacks robust statistical significance.
Summary:
Widespread implementation of CVSM systems on the general ward and potentially outside the hospital seems inevitable. Despite the theoretical benefits of CVSM systems in improving clinical outcomes, and supporting nursing care by optimizing clinical workflow efficiency, the demonstrated effects in clinical practice are mixed. This review highlights the existing challenges related to data quality, usability, implementation, integration, interpretation, and user perspectives, as well as the need for robust evidence to support their impact on patient outcomes, workflow and cost-effectiveness.
Related Concept Videos
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Introduction to Vital Signs
Vital signs help healthcare professionals assess an individual's well-being and detect any functional changes...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...