Related Experiment Video
Updated: Jun 27, 2025

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Factors Influencing the Implementation of Infant Warming Devices Among Healthcare Workers in Malawian Hospitals
Alinane Linda Nyondo-Mipando1, Mai-Lei Woo Kinshella2, Sangwani Salimu1
1Kamuzu University of Health Sciences, Blantyre, Malawi.
Objectives. Preterm infants are at risk of hypothermia. This study described the available infant warming devices (IWDs) and explored the barriers and facilitators to their implementation in neonates in Malawi. Methods. A qualitative descriptive study was conducted among 19 health care workers in Malawi from January to March 2020. All interviews were digitally recorded, transcribed, and managed using NVivo and analyzed using a thematic approach. Results. The warming devices included radiant warmers, Blantyre hot-cots, wall-mounted heaters, portable warmers, and incubators. Inadequate equipment and infrastructure and gaps in staff knowledge and capacity were reported as the main challenges to optimal IWD implementation. Caregiver acceptance was described as the main facilitator. Strategies to optimize implementation of IWD included continuous practical training and adequate availability of equipment and spare parts. Conclusion. Implementation of warming devices for the management of neonatal hypothermia is effective when there are adequate human and material resources.
Objectives. Preterm infants are at risk of hypothermia. This study described the available infant warming devices (IWDs) and explored the barriers and facilitators to their implementation in neonates in Malawi. Methods. A qualitative descriptive study was conducted among 19 health care workers in Malawi from January to March 2020. All interviews were digitally recorded, transcribed, and managed using NVivo and analyzed using a thematic approach. Results. The warming devices included radiant warmers, Blantyre hot-cots, wall-mounted heaters, portable warmers, and incubators. Inadequate equipment and infrastructure and gaps in staff knowledge and capacity were reported as the main challenges to optimal IWD implementation. Caregiver acceptance was described as the main facilitator. Strategies to optimize implementation of IWD included continuous practical training and adequate availability of equipment and spare parts. Conclusion. Implementation of warming devices for the management of neonatal hypothermia is effective when there are adequate human and material resources.
More Related Videos
05:04A Common Marmoset Model of Mother-Infant Intervention for Breastfeeding Disorders in the Presence of Paternal Inhibition and Maternal Neglect
Published on: September 22, 2023
08:08Author Spotlight: Capturing Infant-Caregiver Interactions Through Synchronized Multimodal Data Collection
Published on: May 31, 2024
Related Concept Videos
Factors Affecting Body Temperature
Factors may include:
Decreased Body Temperature
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...