Related Experiment Video
Updated: Jul 14, 2026

Design and Fabrication of an Elastomeric Unit for Soft Modular Robots in Minimally Invasive Surgery
Published on: November 14, 2015
Non-rigid scene reconstruction of deformable soft tissue with monocular endoscopy in minimally invasive surgery
Enpeng Wang1, Yueang Liu1, Jiangchang Xu1
1School of Mechanical Engineering, Shanghai Jiao Tong University, No. 800, Road Dongchuan, Shanghai, 200240, China.
Purpose:
The utilization of image-guided surgery has demonstrated its ability to improve the precision and safety of minimally invasive surgery (MIS). Non-rigid scene reconstruction is a challenge in image-guided system duo to uniform texture, smoke, and instrument occlusion, etc. METHODS: In this paper, we introduced an algorithm for 3D reconstruction aimed at non-rigid surgery scenes. The proposed method comprises two main components: firstly, the front-end process involves the initial reconstruction of 3D information for deformable soft tissues using embedded deformation graph (EDG) on the basis of dual quaternions, enabling the reconstruction without the need for prior knowledge of the target. Secondly, the EDG is integrated with isometric nonrigid structure from motion (Iso-NRSFM) to facilitate centralized optimization of the observed map points and camera motion across different time instances in deformable scenes.
Results:
For the quantitative evaluation of the proposed method, we conducted comparative experiments with both synthetic datasets and publicly available datasets against the state-of-the-art 3D reconstruction method, DefSLAM. The test results show that our proposed method achieved a maximum reduction of 1.6 mm in average reconstruction error compared to method DefSLAM across all datasets. Additionally, qualitative experiments were performed on video scene datasets involving surgical instrument occlusions.
Conclusion:
Our method proved to outperform DefSLAM on both synthetic datasets and public datasets through experiments, demonstrating its robustness and accuracy in the reconstruction of soft tissues in dynamic surgical scenes. This success highlights the potential clinical application of our method in delivering surgeons with critical shape and depth information for MIS.
More Related Videos
10:35Multimodal Imaging and Spectroscopy Fiber-bundle Microendoscopy Platform for Non-invasive, In Vivo Tissue Analysis
Published on: October 17, 2016
07:013D Imaging of Soft-Tissue Samples using an X-ray Specific Staining Method and Nanoscopic Computed Tomography
Published on: October 24, 2019
Related Concept Videos
Endoscopic Studies I: Bronchoscopy and Thoracoscopy
Bronchoscopy
Description
Bronchoscopy is a procedure that involves direct visualization of the larynx, trachea, and bronchi for diagnostic and therapeutic purposes. A flexible fiber optic or rigid bronchoscope is used to carry out the procedure. The fiber-optic bronchoscope is more frequently used due to...
Endoscopic Procedures II: Colonoscopy
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures V: ERCP
Patient...