Abstract:
This article discusses the importance of identifying and preventing human error in industrial environments, specifically in the sugar production process. The article emphasizes the importance of choosing the right technique for risk assessment studies resulting from human errors. A cross-sectional study was conducted using a multi-stage approach - Hierarchical Task Analysis (HTA), Human Error Calculator (HEC), and Predictive Human Error Analysis (PHEA) - to identify potential human errors in the sugar production process. The HTA, HEC, and PHEA techniques were employed to evaluate each stage of the process for potential human errors. The results of the HTA technique identified 35 tasks and 83 sub-tasks in 14 units of the sugar production process. According to HEC technique 4 tasks with 80 % probability of human error and 2 tasks with 50 % probability of human error had the highest calculated error probabilities. The factors of individual skill, task repetition and importance were the most important factors of human error in the present study. The analysis of PHEA worksheets showed that the number of human errors identified in the tasks with highest probability were 8 errors, of which 50 % were action errors, 25 % checking errors, 13 % selection errors, and 12 % retrieval errors. To mitigate the consequences of human error, it was recommended training courses, raising operator awareness of error consequences, and installing instructions in the sugar production process. Based on the findings, the article concludes that the HEC and PHEA techniques are applicable and effective in identifying and analyzing human errors in process and food industries.
More Related Videos
12:02Automated Modular High Throughput Exopolysaccharide Screening Platform Coupled with Highly Sensitive Carbohydrate Fingerprint Analysis
Published on: April 11, 2016
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
Related Concept Videos
Systematic Error: Methodological and Sampling Errors
Sampling errors originate from improper sampling methods or the wrong sample population. These errors can be minimized by refining the sampling strategy. Defective instruments or faulty calibrations are the sources of instrumental...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...