Related Experiment Video
Updated: Jun 27, 2025

Author Spotlight: Advancing Thrombolytic Testing by Integrating Flow Dynamics in In Vitro Models
Published on: April 19, 2024
Tracking Fibrinolysis of Chandler Loop-Formed Whole Blood Clots Under Shear Flow in An In-Vitro Thrombolysis Model
Alexei Christodoulides1, Abigail R Hall1, Anushri Umesh2
1Department of Emergency Medicine, Indiana University School of Medicine.
None:
Thromboembolism and related complications are a leading cause of morbidity and mortality worldwide and various assays have been developed to test thrombolytic drug efficiency both in vitro and in vivo. There is increasing demand for more physiologically relevant in-vitro clot models for drug development due to the complexity and cost associated with animal models in addition to their often lack of translatability to human physiology. Flow, pressure, and shear rate are important characteristics of the circulatory system, with clots that are formed under flow displaying different morphology and digestion characteristics than statically formed clots. These factors are often unrepresented in conventional in-vitro clot digestion assays, which can have pharmacological implications that impact drug translational success rates. The Real-Time Fluorometric Flowing Fibrinolysis (RT-FluFF) assay was developed as a high-fidelity thrombolysis testing platform that uses fluorescently tagged clots formed under shear flow, which are then digested using circulating plasma in the presence or absence of fibrinolytic pharmaceutical agents. Modifying the flow rates of both clot formation and clot digestion steps allows the system to imitate arterial, pulmonary, and venous conditions across highly diverse experimental setups. Measurements can be taken continuously using an in-line fluorometer or by taking discrete time points, as well as a conventional end point clot mass measurement. The RT-FluFF assay is a flexible system that allows for the real-time tracking of clot digestion under flow conditions that more accurately represent in-vivo physiological conditions while retaining the control and reproducibility of an in-vitro testing system.
More Related Videos
08:44An In Vitro Hemodynamic Loop Model to Investigate the Hemocytocompatibility and Host Cell Activation of Vascular Medical Devices
Published on: August 21, 2020
09:19In Vitro Microfluidic Disease Model to Study Whole Blood-Endothelial Interactions and Blood Clot Dynamics in Real-Time
Published on: May 24, 2020
Related Concept Videos
Clot Retraction and Fibrinolysis
Anticoagulant Drugs: Low-Molecular-Weight Heparins