Lucy E Geraghty1, Emma A Dunne1, Caitríona M Ní Chathasaigh1
1From the Departments of Neonatology (L.E.G., E.A.D., C.M.N.C., E.M.O., L.K.M., C.P.F.O.) and Radiology (N.C.A.), National Maternity Hospital, and the School of Medicine (L.E.G., C.M.N.C., E.M.O., L.K.M., C.P.F.O.) and the Centre for Support and Training in Analysis and Research (CSTAR), School of Public Health, Physiotherapy, and Sports Science (A.V.), University College Dublin - both in Dublin.
Background:
Repeated attempts at endotracheal intubation are associated with increased adverse events in neonates. When clinicians view the airway directly with a laryngoscope, fewer than half of first attempts are successful. The use of a video laryngoscope, which has a camera at the tip of the blade that displays a view of the airway on a screen, has been associated with a greater percentage of successful intubations on the first attempt than the use of direct laryngoscopy in adults and children. The effect of video laryngoscopy among neonates is uncertain.
Methods:
In this single-center trial, we randomly assigned neonates of any gestational age who were undergoing intubation in the delivery room or neonatal intensive care unit (NICU) to the video-laryngoscopy group or the direct-laryngoscopy group. Randomization was stratified according to gestational age (<32 weeks or ≥32 weeks). The primary outcome was successful intubation on the first attempt, as determined by exhaled carbon dioxide detection.
Results:
Data were analyzed for 214 of the 226 neonates who were enrolled in the trial, 63 (29%) of whom were intubated in the delivery room and 151 (71%) in the NICU. Successful intubation on the first attempt occurred in 79 of the 107 patients (74%; 95% confidence interval [CI], 66 to 82) in the video-laryngoscopy group and in 48 of the 107 patients (45%; 95% CI, 35 to 54) in the direct-laryngoscopy group (P<0.001). The median number of attempts to achieve successful intubation was 1 (95% CI, 1 to 1) in the video-laryngoscopy group and 2 (95% CI, 1 to 2) in the direct-laryngoscopy group. The median lowest oxygen saturation during intubation was 74% (95% CI, 65 to 78) in the video-laryngoscopy group and 68% (95% CI, 62 to 74) in the direct-laryngoscopy group; the lowest heart rate was 153 beats per minute (95% CI, 148 to 158) and 148 (95% CI, 140 to 156), respectively.
Conclusions:
Among neonates undergoing urgent endotracheal intubation, video laryngoscopy resulted in a greater number of successful intubations on the first attempt than direct laryngoscopy. (Funded by the National Maternity Hospital Foundation; VODE ClinicalTrials.gov number, NCT04994652.).
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy Care I: Pre-procedural Steps
Required Equipment
The equipment necessary for tracheostomy care includes:
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...