External validation of predictive models for new vertebral fractures following percutaneous vertebroplasty
Xiangheng Dai1, Weibin Liao2, Fuzhou Xu2
1Department of Spinal Surgery, Shaoguan First People's Hospital, Guangdong Medical University, Shaoguan, China.
Objective:
To investigate the external validation and scalability of four predictive models regarding new vertebral fractures following percutaneous vertebroplasty.
Methods:
Utilizing retrospective data acquired from two centers, compute the area under the curve (AUC), calibration curve, and Kaplan-Meier plot to assess the model's discrimination and calibration.
Results:
In the external validation of Zhong et al.'s 2015 predictive model for the probability of new fractures post-vertebroplasty, the AUC for re-fracture at 1, 2, and 3 years postoperatively was 0.570, 0.617, and 0.664, respectively. The AUC for Zhong et al.'s 2016 predictive model for the probability of new fractures in neighboring vertebrae was 0.738. Kaplan-Meier plot results for both models indicated a significantly lower incidence of re-fracture in low-risk patients compared to high-risk patients. Li et al.'s 2021 model had an AUC of 0.518, and its calibration curve suggested an overestimation of the probability of new fractures. Li et al.'s 2022 model had an AUC of 0.556, and its calibration curve suggested an underestimation of the probability of new fractures.
Conclusion:
The external validation of four models demonstrated that the predictive model proposed by Zhong et al. in 2016 exhibited superior external generalization capabilities.