Roughness Impact of Piezoelectric Dental Scaler on Two Distinct Flowable Composite Filling Materials
Published on: January 10, 2025
Surface roughness and optical characteristics evaluations after chairside adjustment of different zirconia types
Awab Abdulmajeed1,2, Taiseer A Sulaiman3, Abdulhaq A Suliman4
1Department of Prosthetic Dentistry and Stomatognathic Physiology, Institute of Dentistry, University of Turku, Turku, Finland.
Statement Of Problem:
Limited evidence is available for the effect of chairside adjustment using rotary cutting instruments on the surface roughness and optical properties of different zirconia types.
Purpose:
To evaluate the effect of simulated adjustments on surface roughness and optical properties of different zirconia types.
Materials And Methods:
Three Partially Stabilized Zirconia (PSZ) types based on mole percent yttria (Y) concentration from the same manufacturer (Katana; Kuraray) were used: 3Y-PSZ, 4Y-PSZ, and 5Y-PSZ. Thirty disk-shaped specimens (Ø14 × 1.2 mm) from different zirconia types (N = 90) were prepared. Specimens were either left without adjustment (NA), adjusted with Dialite ZR finishing and polishing system (Brasseler) (APol), or adjusted with course diamond instruments only (ADia). The specimens were distributed into 9 groups (n = 10): Group 3Y-PSZ/NA, Group 3Y-PSZ/APol, Group 3Y-PSZ/ADia, Group 4Y-PSZ/NA, Group 4Y-PSZ/APol, Group 4Y-PSZ/ADia, Group 5Y-PSZ/NA, Group 5Y-PSZ/APol, and Group 5Y-PSZ/ADia. The surface roughness of specimen was analyzed using an Atomic Force Microscope (AFM) (Bruker's Dimension Icon, Bruker) and Root Means Square (RMS) were recorded (nm). Surface Gloss (SG), Translucency Parameter (TP), and Contrast Ratio (CR) values of all groups were recorded using an integrating sphere spectrophotometer. Statistical analysis was performed using analysis of variance (ANOVA) and Tukey's multiple comparison tests for pairwise comparisons at p < 0.05 and 95% confidence interval.
Results:
APol had no effect on the surface roughness (p = 0.88) while ADia had a significant negative effect (p < 0.05) despite the type of zirconia. Out of the three testes optical properties, only SG was negatively affected by ADia for all types of zirconia (p < 0.05). The two adjustment types did not affect the TP of all the tested zirconia (p = 0.91). The CR was not affected by the tested adjustments for all zirconia types (p = 0.726).
Conclusion:
Proper zirconia adjustment following a sequence of burs and polishers can maintain acceptable roughness and optical properties. Adjustment of zirconia with rough diamond can lead to deleterious effects and should be avoided.
Clinical Significance:
Chairside adjustment of zirconia could lead to rougher surface and unpredictable changes of surface gloss. Therefore, zirconia adjustment should be minimized to the greatest extent possible and a proper protocol should be followed if had to be done.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
03:02Impact of Fabrication Techniques and Polishing Procedures on Surface Roughness of Denture Base Resins
Published on: January 17, 2025
Related Concept Videos
Softwoods and Hardwoods
Wood Surfacing
The equipment used in the surfacing process is a plane equipped with rotating blades. This tool efficiently smoothens the wood surface and can...
Lumber Defects
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Shape and Texture of Coarse Aggregate
Toughness and Hardness of Aggregate
Non-destructive Tests for Concrete Strength