Related Experiment Video
Updated: May 8, 2026

Shrinkage of Dental Composite in Simulated Cavity Measured with Digital Image Correlation
Published on: July 21, 2014
Assessments of polymerization shrinkage by optical coherence tomography-based digital image correlation analysis-Part
Wei-Chi Chen1, Shu-Fen Chuang2, Po-Chun Tseng3
1School of Dentistry and Institute of Oral Medicine, National Cheng Kung University, Tainan, Taiwan; Department of Dentistry, Sin-Lau Hospital, Tainan, Taiwan.
Objective:
To investigate the feasibility of optical coherence tomography (OCT)-based digital image correlation (DIC) analysis and to identify the experimental parameters for measurements of polymerization shrinkage.
Methods:
Class I cavities were prepared on bovine incisors and filled with Filtek Z350XT Flowable (Z350F). One OCT image of the polymerized restoration was processed to generate virtually displaced images. In addition, the tooth specimen was physically moved under OCT scanning. A DIC software analyzed these virtual and physical transformation sets and assessed the effects of subset sizes on accuracy. The refractive index of unpolymerized and polymerized Z350F was measured via OCT images. Finally, different particles (70-80 µm glass beads, 150-212 µm glass beads, and 75-150 µm zirconia powder) were added to Z350F to inspect the analyzing quality.
Results:
The analyses revealed a high correlation (>99.99%) for virtual movements within 131 pixels (639 µm) and low errors (<5.21%) within a 10-µm physical movement. A subset size of 51 × 51 pixels demonstrated the convergence of correlation coefficients and calculation time. The refractive index of Z350F did not change significantly after polymerization. Adding glass beads or zirconia particles caused light reflection or shielding in OCT images, whereas blank Z350F produced the best DIC analysis results.
Significance:
The OCT-based DIC analysis with the experimental conditions is feasible in measuring polymerization shrinkage of RBC restorations. The subset size in the DIC analysis should be identified to optimize the analysis conditions and results. Uses of hyper- or hypo-reflective particles is not recommended in this method.
Related Concept Videos
Classification and Mechanical Properties of Synthetic Polymers
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Drying Shrinkage
A portion of this drying shrinkage can be reversed; if the concrete is...

