Smartphone Fundus Photography
Published on: July 6, 2017
Comparing the Diagnostic Utility of Conventional Direct Ophthalmoscopy with Smartphone Ophthalmoscopy among Medical
Jibran Sharieff1, Victoria Bugg1, Zachary C W Barrett2
1Department of Ophthalmology, Dean A McGee Eye Institute, The University of Oklahoma Health Sciences Center, Oklahoma City, Oklahoma.
Abstract:
Purpose To compare the diagnostic ability of medical students using smartphone ophthalmoscopy (SO) with conventional direct ophthalmoscopy (DO). Methods Twenty-eight first- and second-year medical students were trained to use the SO and DO. They also attended educational seminars regarding optic nerve and retinal pathology and were given hands-on practice with each ophthalmoscopy method. Students were randomized 2:1 into one of the groups (DO or SO). Students then examined six patients and recorded their findings, ease of use, and confidence level on a questionnaire. Two attending ophthalmologists, masked to the randomization, graded the student questionnaires. A priori power calculation determined the sample size. The primary outcome measure was the percentage of correct diagnoses the students made. Two-sample t -test, Wilcoxon's rank-sum test, and Fisher's exact test were used to compare the outcomes. Results Students using the SO outperformed students using DO in terms of mean percent correct (% correct) diagnosis (smartphone: 42% vs. direct: 23%; p -value = 0.0057), mean % correct photo match (smartphone: mean = 60% vs. direct: 32%; p -value = 0.0052), and mean % correct nerve/retinal descriptors (smartphone: 72% vs. direct: 59%; p -value = 0.0048). There was not a significant difference in terms of perceived ease of use (smartphone: mean = 3.3 vs. direct: mean = 2.6; p -value = 0.0945), or subjective confidence (smartphone: mean = 2.6 vs. direct: mean = 2.1; p -value = 0.0808) between the two groups. Conclusion SO provides an alternate way for medical students to learn, diagnose, and describe ocular pathology.
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Overview of Microscopy Techniques
Automated Microbial Diagnostics