Accuracy of methods to estimate central aortic SBP via upper arm cuff: a systematic review and meta-analysis
Dean S Picone1,2, Nadège Côté3, Raphaela Corney2
1School of Health Sciences, University of Sydney, Sydney.
Objectives:
Central aortic BP may predict cardiovascular outcomes better than upper arm brachial BP. In recent years, technology has enabled central BP estimation by recording a peripheral BP waveform from a standard upper arm cuff. The accuracy of these devices is not well documented, and this study aimed to address this issue.
Methods:
This study was a systematic review, conducted according to PRISMA guidelines, of observational studies published between 2008 and 2023 that reported accuracy testing of cuff-based central BP devices, compared with reference invasive aortic BP. The primary analysis was stratified according to each commercially available device. Pooled estimates were calculated using random-effects models based on mean differences and standard errors.
Results:
Six thousand four hundred and fifteen studies were screened, and 27 studies met inclusion criteria (plus one unpublished study). This generated data for seven devices that are commercially available, which were tested among 2125 adult participants. There was very high heterogeneity when all devices were pooled ( I2 = 97.5%), and, when stratified by device, the accuracy of estimated central BP was highly device-dependent (range of accuracy across different devices -12.4 mmHg (-16.3 to -8.5) to 3.2 mmHg (0.2-6.1). Two of the seven commercially available devices had not undergone external validation testing.
Conclusion:
The accuracy of commercially available cuff-based central BP devices is highly device-specific and not all are accurate for the estimation of central SBP. These findings have major implications for the appropriate interpretation of studies that use cuff-based estimated central BP.
Related Concept Videos
Sites for measruring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure