Related Experiment Video
Updated: Jun 26, 2025

Acupoint Needle-Embedding Combined with Ironing Therapy for Postoperative Pain After Anal Surgery
Published on: June 23, 2023
Diode laser hemorrhoidoplasty versus conventional Milligan-Morgan and Ferguson hemorrhoidectomy for symptomatic
Po-Lung Cheng1, Chang-Cyuan Chen2, Jian-Syun Chen3
1Department of General Medicine, Taipei Medical University Hospital, Taipei City, Taiwan.
Abstract:
Conventional hemorrhoidectomy is the mainstay of treatment for symptomatic haemorrhoids, but reported postoperative complications remains the main concern. On the contrary, with its minimally invasive nature, laser hemorrhoidoplasty showed the potential to reduce postoperative complications and discomfort. Therefore, we performed a systemic review and meta-analysis to evaluate the postoperative outcome of laser hemorrhoidoplasty compared to conventional hemorrhoidectomies, including Milligan-Morgan and Ferguson techniques. Of all studies from PubMed, EMBASE, Cochrane database, and Google Scholar, we included 17 trials with 1196 patients, of whom 596 (49.8 %) underwent laser hemorrhoidoplasty and 600 (50.2 %) underwent conventional hemorrhoidectomy. The primary outcomes were operative blood loss and postoperative haemorrhage, and the secondary outcomes were the operative time, postoperative pain score, complications, and haemorrhoid recurrence. In this study, we found that laser hemorrhoidoplasty showed benefits in operative blood loss (weighted mean difference [WMD]: -16.43 ml, 95 % confidence interval [CI]: -23.82 to -9.04), postoperative hemorrhage/bleeding (odds ratio [OR]: 0.16, 95 % CI: 0.10 to 0.28), operative time (WMD: -12.42 min, 95 % CI: -14.56 to -10.28), postoperative pain score on day 1 (WMD: -2.50, 95 % CI: -3.13 to -1.88), and anal stenosis (OR: 0.14, 95 % CI: 0.03 to 0.65) in comparison with conventional hemorrhoidectomy. However, incidence of fecal/flatus incontinence, urinary retention and hemorrhoid recurrence were not significantly different between the 2 groups. Consistent results were found in 5 subgroup analyses, including studies with low risk of bias, studies using 1470 nm laser, and studies using 980 nm laser, studies conducted in Asia, and studies conducted in Europe and America.
More Related Videos
05:28Enucleation of the Prostate for the Treatment of Benign Prostatic Hyperplasia Using a 980 nm Diode Laser
Published on: May 5, 2020
05:46Introduction of Intracapsular Rotary-cut Procedures IRCP: A Modified Hysteromyomectomy Procedures Facilitating Fertility Preservation
Published on: January 17, 2019