Related Experiment Video
Updated: Jun 25, 2025

Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
New Generation Nebulizers
1PARI Pharma GmbH, Starnberg, Germany (Emeritus); R&D and President.
None:
Standard nebulizers are intended for general purpose use and typically are continuously operated jet or ultrasonic nebulizers. Evolutionary developments such as breath-enhanced and breath-triggered devices have improved delivery efficiency and ease of use, yet are still suitable for delivery of nebulized medications approved in this category. However, recent developments of vibrating membrane or mesh nebulizers have given rise to a significant increase in delivery efficiency requiring reformulation of former drug products or development of new formulations to match the enhanced delivery characteristics of these new devices. In addition, the electronic nature of the new devices enables tailoring to specific applications and patient groups, such as guiding or facilitating optimal breathing and improving adherence to the therapeutic regimen. Addressing these patient needs leads to new nebulization technologies being embedded in devices with fundamentally distinct functionality, modes of operation and patient interfaces. Therefore, new generation nebulizers can no longer be regarded as one category with fairly similar performance characteristics but must be clinically tested and approved as drug/device combinations together with the specific drug formulation, similar to the approval of pressurized metered-dose inhalers and dry powder inhalers. From a regulatory viewpoint, it is required that drug and device are associated with each other as combinations by clear, mutually conforming labels or, even more desirably, by distinct container-closure systems (closed system nebulizer).
Related Concept Videos
Inhaled Medications
Suctioning the Nasopharyngeal Airway
Equipment Required
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Asthma-IV: Diagnostic and Management
Clinical Assessment for Asthma:
This is the first step in diagnosing and managing asthma. It includes:
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...