A comparison of methods for in vivo activity and absorbed dose quantification with PET/CT following yttrium-90
Eric Courtney Henry1, Armeen Mahvash2, Benjamin P Lopez1
1Department of Imaging Physics, University of Texas MD Anderson Cancer Center, Houston, Texas, USA.
Background:
Yttrium-90 (90Y) positron emission tomography (PET)/computed tomography (CT) imaging is increasingly being used to perform tumor (T) and normal liver (NL) voxel dosimetry after 90Y-radioembolization (90Y-RE). Yet, the accuracy of in vivo 90Y-PET/CT imaging, subject to motion blur and co-registration inaccuracies, and 90Y-PET/CT dose quantification, subject to availability of different voxel dosimetry algorithms, are not well understood.
Purpose:
The purpose of this study was to investigate the accuracy of 90Y-PET/CT-based activity estimates following 90Y-RE and characterize differences between 90Y-PET/CT-based voxel dosimetry algorithms.
Methods:
Thirty-five patients underwent 90Y-PET/CT imaging after 90Y-RE with TheraSphere. The net administered 90Y activity (Aadmin) was determined using a dose calibrator and pre- and post-procedure exposure rate measurements. The summation of image-based activity (Aimage) was extracted from perfused volume (PV) and 3D-isotropically 2-cm expanded PV contour (PV+2 cm). Absorbed doses were calculated using voxel S-value (VSV), local deposition method (LDM), and LDM with known activity (LDMKA) dosimetry algorithms. Linear regression and Bland-Altman analysis quantified the relationship between Aimage and Aadmin and between mean dose estimates (DLDM, DVSV, DLDM-KA) for PV, T, and perfused NL volumes.
Results:
While Aadmin and Aimage in PV were highly correlated (R2 > 0.95), the mean bias ± standard error (SE) and (95% limits of agreement, LOA) was significantly non-zero with -22.7 ± 4.7% (± 28.4%). In PV+2 cm, the mean bias ± SE (± LOA) decreased to 1.3 ± 3.4% (± 18.0%) consistent with zero mean error. DLDM and DVSV were highly correlated (R2 > 0.99) for all volumes of interest (VOIs) and the mean bias ± SE (± LOA) was 2.2 ± 0.2% (± 1.0%), 0.7 ± 0.4% (± 2.8%), and 3.2 ± 0.5% (± 2.8%) for PV, T, and NL, respectively. DLDM-KA and DVSV were correlated with R2 = 0.86, 0.80, and 0.86 for PV, T, and NL, respectively. The mean bias ± SE (± LOA) between DLDM-KA and DVSV was significantly non-zero with -19.6 ± 5.1% (± 31.0%), -20.8 ± 4.4% (± 29.0%), and -18.1 ± 5.3% (± 31.1%) for PV, T, and NL, respectively.
Conclusions:
The summation of Aimage in PV was underestimated relative to Aadmin. Only by accounting for respiratory motion, limited spatial resolution, and PET/CT co-registration errors through VOI expansion was Aimage, on average, equal to Aadmin. The differences between DLDM and DVSV were not clinically relevant, though DLDM-KA was approximately 20% greater than DVSV. Given the high quantitative accuracy of dose calibrators and challenges associated with accurate 90Y-PET/CT quantification, LDMKA is the preferred algorithm for accurate 90Y-PET/CT-based dosimetry following 90Y-RE.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
10:04Radionuclide-fluorescence Reporter Gene Imaging to Track Tumor Progression in Rodent Tumor Models
Published on: March 13, 2018
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...