Machine learning-based analysis of non-invasive measurements for predicting intracardiac pressures
Annemiek E van Ravensberg1, Niels T B Scholte1, Aaram Omar Khader1
1Department of Cardiology, Erasmus MC, Cardiovascular Institute, Thorax Center, Doctor Molewaterplein 40, 3015 GD Rotterdam, The Netherlands.
Aims:
Early detection of congestion has demonstrated to improve outcomes in heart failure (HF) patients. However, there is limited access to invasively haemodynamic parameters to guide treatment. This study aims to develop a model to estimate the invasively measured pulmonary capillary wedge pressure (PCWP) using non-invasive measurements with both traditional statistics and machine learning (ML) techniques.
Methods And Results:
The study involved patients undergoing right-sided heart catheterization at Erasmus MC, Rotterdam, from 2017 to 2022. Invasively measured PCWP served as outcomes. Model features included non-invasive measurements of arterial blood pressure, saturation, heart rate (variability), weight, and temperature. Various traditional and ML techniques were used, and performance was assessed using R2 and area under the curve (AUC) for regression and classification models, respectively. A total of 853 procedures were included, of which 31% had HF as primary diagnosis and 49% had a PCWP of 12 mmHg or higher. The mean age of the cohort was 59 ± 14 years, and 52% were male. The heart rate variability had the highest correlation with the PCWP with a correlation of 0.16. All the regression models resulted in low R2 values of up to 0.04, and the classification models resulted in AUC values of up to 0.59.
Conclusion:
In this study, non-invasive methods, both traditional and ML-based, showed limited correlation to PCWP. This highlights the weak correlation between traditional HF monitoring and haemodynamic parameters, also emphasizing the limitations of single non-invasive measurements. Future research should explore trend analysis and additional features to improve non-invasive haemodynamic monitoring, as there is a clear demand for further advancements in this field.
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure