Related Experiment Video
Updated: Jun 25, 2025

Infrared Degenerate Four-wave Mixing with Upconversion Detection for Quantitative Gas Sensing
Published on: March 22, 2019
Highly sensitive sensing of CO and HF gases by monolayer CuCl
Shamiala Pervaiz1, M Usman Saeed1, Sehrish Khan1
1Department of Physics, Abbottabad University of Science and Technology Abbottabad KPK Pakistan yasir.saeed@kaust.edu.sa yasirsaeedphy@aust.edu.pk +(92)-3454041865.
Abstract:
Using a first-principles approach, the adsorption characteristics of CO and HF on a CuCl monolayer (ML) are studied with Grimme-scheme DFT-D2 for accurate description of the long-range (van der Waals) interactions. According to our study, CO gas molecules undergo chemisorption and HF gas molecules show a physisorption phenomenon on the CuCl monolayer. The adsorption energy for CO is -1.80 eV, which is quite a large negative value compared to that on other previously studied substrates, like InN (-0.223 eV), phosphorene (0.325 eV), Janus Te2Se (-0.171 eV), graphene (P-graphene, -0.12 eV, B-graphene, -0.14 eV, N-graphene, -0.1 eV) and monolayer ZnS (-0.96 eV), as well as pristine hBN (0.21 eV) and Ti-doped hBN (1.66 eV). Meanwhile, for HF, the adsorption energy value is -0.31 eV (greater than that of Ti-doped hBN, 0.27 eV). For CO, the large value of the diffusion energy barrier (DEB = 1.26 eV) during its movement between two optimal sites indicates that clustering can be prevented if many molecules of CO are adsorbed on the CuCl ML. For HF, the value of the DEB (0.082 eV) implies that the adsorption phenomenon may happen quite easily upon the CuCl ML. The transfer of charge according to Bader charge analysis and the variation in the work function depend only on the properties of the elements involved, i.e., their nature, rather than the local binding environment. The work function and band-gap energy variation of the CuCl ML (before and after adsorption) show high sensitivity and selectivity of CO and HF binding with the CuCl monolayer. HF molecules give a more rapid recovery time of 1.09 × 10-7 s compared to that of CO molecules at a room temperature (RT) of 300 K, which indicates that the necessary adsorption and reusability of the CuCl ML for HF can be accomplished effectively at RT. Significant changes in the conductivity are observed due to the CO adsorption at various temperatures, as compared to adsorption of HF, which suggests the possibility of a modification in the conductivity of the CuCl ML.
More Related Videos
11:38In situ FTIR Spectroscopy as a Tool for Investigation of Gas/Solid Interaction: Water-Enhanced CO2 Adsorption in UiO-66 Metal-Organic Framework
Published on: February 1, 2020
06:36Preparation of Expanded Chitin Foams and their Use in the Removal of Aqueous Copper
Published on: February 27, 2021
Related Concept Videos
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...