Related Experiment Video
Updated: Jun 25, 2025

Infrared Thermography for the Detection of Changes in Brown Adipose Tissue Activity
Published on: September 28, 2022
The accuracy of Infrared sensor detection in a smart toilet
Amar Lokman1, Kirenraj Rajendran1, R Kanesaraj Ramasamy1
1Faculty of Computing and Informatics, Multimedia university, Cyberjaya, Selangor, 63100, Malaysia.
Abstract:
Background: Infrared (IR) sensors are useful tools for detecting distance and proximity. However, these sensors are not good at detecting edges of an area, therefore when used in a smart toilet it has difficulty in detecting the orientation and position of the user's body. The aim of this study was to design an IR sensor for a smart toilet with a more accurate and consistent detection. Methods: A total of 12(six men and six women) participants with different body types were involved in this study. IR sensor detection was tested in the sitting and squatting toilets. For the best accuracy, the IR sensor's angle was measured. Red, blue, and red-blue plastic covers were used, as these colors improve precision. The microcontroller was set up to calculate the participant's distance and presence in the cubicle. Results: Toilet positioning varied greatly depending on whether one is sitting or squatting. For sitting toilet, the red cover was close to the accurate distance at a 172° angle. IR detected a man but not a woman's body. The blue cover provided the same best angle of 172° with a higher sensor distance. When the red and blue cover combination was applied, the reading of 141cm detected both men and women, at 172° angle. The actual distance for squatting toilets was 158cm. The optimal angle for both red and blue covers was 176°, however the sensor distance was greater for the blue cover. Finally, the red and blue cover combination gave a more accurate distance of up to 163cm from the actual reading, when detecting both genders at a normal angle of 76°. Conclusion: The combination of red and blue cover gave the most accurate detection for the squatting and sitting toilets. The best angle for sitting was 172°, and for squatting was 176°.
Related Concept Videos
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
IR Spectrometers
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...