Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
Published on: February 14, 2025
Modified Tilt-integral active disturbance rejection controller with inertia emulated direct current link for
Abdul Latif1, S M Suhail Hussain2, Ahmed Al-Durra1
1Advanced Power & Energy Center, EECS Department, Khalifa University, Abu Dhabi, United Arab Emirates.
Abstract:
The increasing integration of intermittent renewable sources (RSs) poses a dynamic frequency stability challenge for modern marine vessel microgrids. To address this issue, this paper proposes a novel control approach, specifically targeting frequency and tie-line power stabilization in a diverse source marine microgrid (MμG) with two intertied areas featuring renewable (wind-wave) sources. The suggested approach introduces a modified tilt-integral active disturbance rejection (TI-ADRC) controller designed to ensure effective damping of power frequency oscillations. As the control scheme depends on the optimal setting of the proposed controller, a recently developed marine predator technique (MPT) has been adopted. The performance of the proposed controller is compared with other recent controllers viz. PID, tilt-integral derivative (TID), two-degree-of-freedom (2DOF)-PID, fuzzy-PI, and ADRC to validate its superiority. To further enhance the system dynamics, a precise modeling of inertia emulated direct current (IEPDC) tie link is incorporated in microgrid system. The impact assessments, considering time delays with pre/post IEPDC link, demonstrate a substantial 57.79% and 81.53% reduction in peak frequency overshoot compared to DC link (conventional model) and AC link, respectively. The analysis of the eigen plot confirms the stability of the control system. Sensitivity assessments of the controller against ± 30% parametric variations and load fluctuations are conducted, affirming its robustness. Finally, the result from OPAL-RT confirm the practicality of the proposed method. It is asserted that the suggested controller is reliable and functions well in n the presence of diverse disruptions and parametric variations.
More Related Videos
08:35Interactive and Visualized Online Experimentation System for Engineering Education and Research
Published on: November 24, 2021
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
Related Concept Videos
Load-frequency control
Time and frequency -Domain Interpretation of PI Control
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
Turbine-Governor Control
Phase-lead and Phase-lag Controllers
Generator Voltage Control
Induced Electric Fields: Applications