Related Experiment Video
Updated: Jun 25, 2025

Author Spotlight: Enhancing Vascular Function and Physical Capacity in Cardiovascular Disease Through Novel Interventions and NIRS Technology
Published on: March 22, 2024
Estimation of differential pathlength factor from NIRS measurement in skeletal muscle
B Koirala1, A Concas2, A Cincotti2
1Department of Electrical and Computer Engineering, Old Dominion University, Norfolk, VA, USA; Department of Orthopedic Surgery, Washington University, St. Louis, MO, USA.
Abstract:
The utilization of continuous wave (CW) near-infrared spectroscopy (NIRS) device to measure non-invasively muscle oxygenation in healthy and disease states is limited by the uncertainties related to the differential path length factor (DPF). DPF value is required to quantify oxygenated and deoxygenated heme groups' concentration changes from measurement of optical densities by NIRS. An integrated approach that combines animal and computational models of oxygen transport and utilization was used to estimate the DPF value in situ. The canine model of muscle oxidative metabolism allowed measurement of both venous oxygen content and tissue oxygenation by CW NIRS under different oxygen delivery conditions. The experimental data obtained from the animal model were integrated in a computational model of O2 transport and utilization and combined with Beer-Lambert law to estimate DPF value in contracting skeletal muscle. A 2.1 value was found for DPF by fitting the mathematical model to the experimental data obtained in contracting muscle (T3) (Med.Sci.Sports.Exerc.48(10):2013-2020,2016). With the estimated value of DPF, model simulations well predicted the optical density measured by NIRS on the same animal model but with different blood flow, arterial oxygen contents and contraction rate (J.Appl.Physiol.108:1169-1176, 2010 and 112:9-19,2013) and demonstrated the robustness of the approach proposed in estimating DPF value. The approach used can overcome the semi-quantitative nature of the NIRS and estimate non-invasively DPF to obtain an accurate concentration change of oxygenated and deoxygenated hemo groups by CW NIRS measurements in contracting skeletal muscle under different oxygen delivery and contraction rate.
More Related Videos
09:33Using Near-Infrared Spectroscopy Wearable Devices to Identify Central Versus Peripheral Limitations During Exercise
Published on: December 19, 2024
09:04Skeletal Muscle Neurovascular Coupling, Oxidative Capacity, and Microvascular Function with 'One Stop Shop' Near-infrared Spectroscopy
Published on: February 20, 2018