Related Experiment Video
Updated: Jun 25, 2025

The Rigid Tube as an Alternative in Controlling the Problematic Airway
Published on: June 6, 2020
Hyperangulated vs. Macintosh videolaryngoscopy in adults with anticipated difficult airway management: a randomised
Vera Köhl1, Viktor A Wünsch1, Marie-Claire Müller1
1Department of Anaesthesiology, Centre for Anaesthesiology and Intensive Care Medicine, University Medical Centre Hamburg-Eppendorf, Hamburg, Germany.
Background:
It is not certain whether the blade geometry of videolaryngoscopes, either a hyperangulated or Macintosh shape, affects glottic view, success rate and/or tracheal intubation time in patients with expected difficult airways. We hypothesised that using a hyperangulated videolaryngoscope blade would visualise a higher percentage of glottic opening compared with a Macintosh videolaryngoscope blade in patients with expected difficult airways.
Methods:
We conducted an open-label, patient-blinded, randomised controlled trial in adult patients scheduled to undergo elective ear, nose and throat or oral and maxillofacial surgery, who were anticipated to have a difficult airway. All airway operators were consultant anaesthetists. Patients were allocated randomly to tracheal intubation with either hyperangulated (C-MAC D-BLADE™) or Macintosh videolaryngoscope blades (C-MAC™). The primary outcome was the percentage of glottic opening. First attempt success was designated a key secondary outcome.
Results:
We assessed 2540 adults scheduled for elective head and neck surgery for eligibility and included 182 patients with expected difficult airways undergoing orotracheal intubation. The percentage of glottic opening visualised, expressed as median (IQR [range]), was 89 (69-99 [0-100])% with hyperangulated videolaryngoscope blades and 54 (9-90 [0-100])% with Macintosh videolaryngoscope blades (p < 0.001). First-line hyperangulated videolaryngoscopy failed in one patient and Macintosh videolaryngoscopy in 12 patients (13%, p = 0.002). First attempt success rate was 97% with hyperangulated videolaryngoscope blades and 67% with Macintosh videolaryngoscope blades (p < 0.001).
Conclusions:
Glottic view and first attempt success rate were superior with hyperangulated videolaryngoscope blades compared with Macintosh videolaryngoscope blades when used by experienced anaesthetists in patients with difficult airways.
More Related Videos
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Assessment of Airway, Skin Color, and Use of Accessory Muscles
Introduction
The initial evaluation of a patient's respiratory system...

